3.1 TECHNICAL CHARACTERISTICS

 

DESCRIPTION 

RANGE 

UNIT 

Supply voltage 

24

 

Vac 

Input current 

Aac 

Rated Frequency 

50/60 

Hz 

Electrical characteristics 

DESCRIPTION 

RANGE 

Operating temperature 

 - 30°C ÷ + 70°C 

Storage temperature 

- 40°C ÷ + 85°C 

Protection degree 

IP 20 

Cable cross section, min / max 

0,5 / 2,5 mm² 

Electrical characteristics 

DESCRIPTION 

NORMS 

EMC Directive 

89/336/EEC 

Low Voltage 

93/68/EEC 

Safety of information Technology Equipment, including Electrical Business 
Equipment 

EN60950 

EMC Generic Immunity Standard (Industrial) 

EN61000-6-2 

EMC Generic Emission Standard (Industrial) 

EN61000-6-4 

Certifications and Compliance 

Summary of Contents for 08880893

Page 1: ...tronica S r l Via E Ferrari 28 30037 Scorz VE Italy Tel 39 041 5841973 Fax 39 041 5841979 www almot it info almot it 08880893 CONTROL UNIT FOR 1 MOTOR 24 VOLT ITALIANO Versione 1 31 03 2015 MANUAL INS...

Page 2: ...ety Don t clean or wash the device with solvent or jets of water Do not immerse into water Warning in case of damage or malfunction turn off the device from the general switch and call a qualified tec...

Page 3: ...S G Elettronica S r l Via E Ferrari 28 30037 Scorz VE Italy Tel 39 041 5841973 Fax 39 041 5841979 www almot it info almot it 1 3 0 WIRING DIAGRAM...

Page 4: ...stics DESCRIPTION RANGE Operating temperature 30 C 70 C Storage temperature 40 C 85 C Protection degree IP 20 Cable cross section min max 0 5 2 5 mm Electrical characteristics DESCRIPTION NORMS EMC Di...

Page 5: ...POWER SUPPLY M2 INPUTS AND OUTPUTS RA RS485 A line 9 RB RS485 B line 8 CO RS485 commom 0 V 7 NO Alarm relay N O contact 6 NC Alarm relay N C contact 5 KAL Alarm relay Common contact 4 NO FC relay N O...

Page 6: ...nr 1 Device versions 4 1 REPORTS The device manages many kinds of led light flashes summarized in picture 1 4 2 ALARM RESET The device comunicates outdoors it s status with two led red and green the b...

Page 7: ...status If the device detects a wind speed greater then the threshold or the rain sensor is active the device goes in the alarm state closing the window When the alarm condition is removed the device...

Page 8: ...mittent sound 5 POGRAMMING OR RESET DONE 6 1 MEMORIZATION OF A TX FROM A 893 CONTROL UNIT BEEEEEEP BEEEEEEP BEP BEP BEP BEP BEP BEP 6 3 TOTAL RESET 1 When the control unit is powered push and keep pre...