16
Content
1. Safety Precautions ........................................................................................................................................................................................... 17
2. General Information ......................................................................................................................................................................................... 17
2.1. Scope of Supply, unpacking and Setting Up .............................................................................................................................................. 17
2.2. Ernergy Harvesting (manual pull tester FMT-W30 only) .............................................................................................................................. 17
2.3. Attach the 24V DC power supply (motorized pull tester FMT-W40 only) ...................................................................................................... 17
2.3 Instrument overview ................................................................................................................................................................................. 18
3. Operating procedures ..................................................................................................................................................................................... 18
3.1 Turn the instrument ON/OFF ...................................................................................................................................................................... 18
3.2 General information about the display und function of the keypad during and in between the measurements .......................................... 18
3.3 Preparing the measurement ...................................................................................................................................................................... 19
3.4 Start measuring (AutoTara) with manual pull tester FMT-W30 .................................................................................................................... 20
3.5 Memorize measuring values with manual pull tester FMT-W30 .................................................................................................................. 20
3.6 Start measuring (AutoTara) with motorized pull tester FMT-W40 ................................................................................................................. 21
3.7 Automatic memorizing of measured values with motorized pull tester FMT-W40 ........................................................................................ 21
3.8 Display statistical data ............................................................................................................................................................................. 22
3.9 Delete displayed data and statistics ......................................................................................................................................................... 22
4. Tensile force limit control ............................................................................................................................................................................... 22
4.1. Setting of limits ........................................................................................................................................................................................ 23
5. Data transfer and generating a test report with FMT-W_Connect ...................................................................................................................... 23
5.1 System requirements................................................................................................................................................................................. 23
5.2 Installation / Activate the Excel AddIn ....................................................................................................................................................... 24
5.3 Start FMT-W_Connect ................................................................................................................................................................................ 24
5.4 Save and printout measuring protocol ....................................................................................................................................................... 26
6. General settings (P1), Setting of memory (P2) and reset works defaults (Po) ................................................................................................... 27
7. Technical data ................................................................................................................................................................................................ 28
8. Maintenance and calibration .......................................................................................................................................................................... 28
8.1 5-Years extended warranty ........................................................................................................................................................................ 28
8.2 Register for updates .................................................................................................................................................................................. 29
9.0 Trouble shooting (FAQ) ................................................................................................................................................................................. 30
10.0 Accessories (Exchangable terminal fixtures) ............................................................................................................................................... 30