TESTING THE OPERATOR LOCK
The LP1000 is equipped with an operator locking mechanism. The lock
is only active when the operator is powered and the GATE CLOSED
light is on.
When power is OFF, the lock is not energized and the gate may be
pushed open manually.
SMART™ SETTING - SELF ADJUSTING MAXIMUM
RUN TIMER
The LP1000 is equipped with a
S
elf adjusting
MA
ximum
R
un
T
imer,
SMART™, that will turn the LP1000 OFF if a Limit Switch command
is not received within a few seconds of the time required to fully Open
or Close the gate. Valid commands received during the cycle, such as
activation of the OVERLOAD or a new input command, will
automatically reset and restart the MRT.
To set the SMART™ Maximum Run Time and check that the limits are
properly adjusted, fully open and close the gate five (5) times. The
control board will sense the time required and add approximately two
seconds.
BI-PARTING INSTALLATION FINAL SETTINGS
LIMIT SWITCHES - Push both gates together in the center of the
driveway to set the closed limits. Push each gate open an equal amount
to set the open limits. After cycling the gates the settings can be fine
tuned to insure that the gates stop in their open positions at the same
time.
SWITCH SELECTABLE OPTIONS - Make sure the selectable option
on switch #3 is set in the ON position for the primary operator and the
OFF position for the secondary operator. Set the primary operator’s
other two switches to the desired position according to the functions
required. The settings of the secondary operator’s other switches must
be OFF.
When properly adjusted, the two operators will perform as if they were a
true Master/Slave installation. If the motor overload circuit in one
operator should respond to an obstruction not encountered by the other,
the gates will temporarily get out of sync. Synchronization will be
restored after the next input command cycle..
D
: STARTING THE OPERATOR
#
NAME
DESCRIPTION
1
24 VAC
Provides maximum 10 VA auxiliary
power for accessories.
2
24 VAC
Provides maximum 10 VA auxiliary
power for accessories.
3
ALTERNATE
Momentary input, must be released
and re-entered to be recognized.
This input is used for “COMMAND OPEN/COMMAND CLOSE”
applications. The 1st signal will cause the gate to begin
opening. A 2nd signal received during the open cycle will stop
the gate immediately. A 3rd signal will close the gate. Connect
appropriate access control devices to this terminal and #16
COMMON. Disable the Close Timer (rotate pot fully counter-
clockwise).
4
RADIO OPEN
Momentary input, must be released
and re-entered to be recognized.
Once activated the gate will open fully. Activation while the gate
is closing will cause it to re-open.
5
FREE EXIT
Momentary or continuous input.
Once activated the gate will open fully. Activation while the gate
is closing will cause it to re-open. Continuous activation while
the gate is open will prevent the Timer-To-Close function from
automatically closing the gate.
6
OPEN
Momentary or continuous signal. On/
Off mode set by Switch #1
WITH SWITCH 1 OFF:
Once activated the gate will open fully.
Activation while the gate is closing will cause it to re-open.
Continuous activation while the gate is open will prevent the
Timer-To-Close function from automatically closing the gate.
Continuous signal required to move the gate when in the alarm
mode.
WITH SWITCH 1 ON:
Gate does not respond to
pushbutton input when in the normal mode. Continuous signal
required to move the gate when in the alarm mode.
TERMINAL STRIP REFERENCE CHART
Terminal Strip Reference Chart continued on next page