: STARTING THE OPERATOR  

SETTING THE OBSTRUCTION DETECTION /
SENSITIVITY 

The operator is 
equipped with an 
o b s t r u c t i o n 
detection circuit 
which will detect 
M

O

S

obstructions in the 
gate's path.  See 
Figure 19. The 
sensitivity can be 
i n d e p e n d e n t l y 
adjusted for OPEN 
and CLOSE with 
the potentiometers 

on the controller board labeled, 
"OVERLOAD FORCE".  Turning a 
potentiometer clockwise decreases the 
s e n s i t i v i t y   a n d   t u r n i n g   i t 
c ount e rclo c kwis e  i n cr eas es t h e 
sensitivity. 

The LP1000 is shipped from the factory with 

the potentiometers at their most sensitive setting.  Turn the potentio-
meter 1/4 turn clockwise to prevent the overload circuit from tripping 
due to the gate's inherent friction.   

 (See FINAL SETTING OF THE OBSTRUCTION DETECTION 
SENSITIVITY, P 16.) 

SETTING THE SWITCH SELECTABLE OPTIONS 

There are three (3) option selection switches on the LP1000 controller 
board that result in four (4) switch selectable options. Please review 
Figure 20.  The switches are contained in a 3-pole dip switch package at 
the bottom right of the board.  The text that follows describes each of 
the options they select. 

NO-LOAD TEST MODE 

To run/test the LP1000 operator 
when it is not connected to a gate 
leaf, turn all of the switches to 
the “ON” position.  The LP1000 
can then be operated without a gate leaf attached for 20 complete 
cycles.  If more that twenty cycles are attempted in the test mode the 
operator control board changes to a “sleep” mode and a low pulsed tone 
is heard from the audible output.  You can reset the operator for a 
renewed 20 test cycles by turning the power off and back on again.  To 
return to normal operation turn one of the switches to the “OFF” 
position, then set all the switches to the desired mode of operation as 
described in the text that follows.

AlarmAble™ OPEN/CLOSE PUSH BUTTON 
ENABLE/DISABLE (PATENT NO. 6,611,205) 

Switch S1 controls the Push Button Enable/Disable Feature. 

SWITCH 1 OFF:

 Activating the Open or Close buttons the gate will 

open or close fully.  Activation of the Open while the gate is closing 
will cause it to re-open.  Activation of the Close while the gate is 
opening has no effect.  Continuous activation of an opposing button 
while the gate is on a limit will prevent operation in that direction. 
Continuous signal required to move the gate when in the alarm mode. 

SWITCH 1 ON:

 Gate does not respond to pushbutton input when in 

the normal mode. Continuous signal required to move the gate when in 

RISK OF ELECTROCUTION 

DO NOT BEGIN TO SET OR RESET THE 

FOLLOWING ADJUSTMENTS  UNTIL THE POWER 

IS TURNED OFF AT THE LP1000 CONTROL BOX 

             W A R N I N G !  

RISK OF ENTRAPMENT. 

THE OVERLOAD POTENTIOMETER MUST BE 

SET MORE PRECISELY PRIOR TO COMPLETING 

THE OPERATOR INSTALLATION  

             W A R N I N G !  

LOCATION OF 

SWITCH SELECT-

ABLE OPTIONS

Figure 20:  

Switch

Selectable 

Options 

LOCATION OF 

OVERLOAD FORCE

ADJUSTMENTS

110126 

110124 

Figure 19:  Overload 

Force Adjustments 

LOCATION OF 

AUTOCLOSE TIMER

ADJUSTMENT

Figure 21: Location of Auto-Close Timer Adjustment 

110125 

Summary of Contents for LEADER PLUS LP1000

Page 1: ...rements for Vehicular gate operators LEADER PLUS Model LP1000 Heavy Duty Vehicular Slide Gate Operator READ THIS MANUAL CAREFULLY BEFORE INSTALLATION OR USE SAVE THESE INSTRUCTIONS 107063 Serial Date...

Page 2: ...there to protect you and your equipment Pay close attention to these boxes as you follow the manual WARNING Indicates a MECHANICAL hazard of INJURY OR DEATH Gives instructions to avoid the hazard CAU...

Page 3: ...TE TESTED ON THE LOG LOCATED ON PAGE 2 OF THIS MANUAL See Figure 1 pg 2 Connections for External Entrapment Prevention Sensors Because all gate system installations are different the LP1000 control pa...

Page 4: ...IAL HAZARD CAN BE MINIMIZED BY INSTALLING A MESH SCREEN ON THE GATE Allstar strongly recommends the entire gate and adjacent fence area the gate covers when open be meshed or guarded such that a handh...

Page 5: ...be exposed EVEN IF THE RED POWER LIGHT IS NOT LIGHTED HIGH VOLTAGE AC MAY STILL BE PRESENT ON TERMINALS L1 AND L2 NEVER LEAVE THE INSTALLATION WITH THE CONTROL BOX COVER REMOVED x ALWAYS TURN OFF THE...

Page 6: ...tor The bolt pattern for the LP1000 is 12 3 16 wide by 12 1 4 long The two rear bolts closest to the gate should be no closer than 5 1 2 from the near side of the gate to allow sufficient clearance fo...

Page 7: ...ol wires MUST NEVER be routed in the same conduit as A C power wires Always consult and follow all local electrical codes 106728 Figure 8 Chain Configuration Normal Drive Figure 7 Service Conduits 106...

Page 8: ...d in wires need not be in PVC but must have at least six 6 twists per running foot For a saw cut installation observe the method recommended in Figurez10 for the corners When installing a two loop rev...

Page 9: ...with the operator in place Before inserting the remaining redhead bolts make sure the operator is sitting level If any corners of the operator are resting above the pad slide flat washers under the op...

Page 10: ...100 OHMS resistance and for more than 100 milliseconds duration Two of the inputs ALTERNATE and RADIO OPEN are momentary inputs where the signal must be released and re entered to be recognized The r...

Page 11: ...parate from the receiver s output connection This is necessary as the LP1000 control board 24 VAC is isolated from chassis ground A 3 prong receiver CANNOT be installed in association with the LP1000...

Page 12: ...factory configured for right hand installations If it is installed in a left hand installation make sure the main power switch is off and locate the 8 pin motor wire connector in the upper center of t...

Page 13: ...limit nut two more slots to give the operator time to stop the gate after the limit switch has been activated Release the detent plate and make sure it drops into the slots on both limit nuts Manually...

Page 14: ...he test mode the operator control board changes to a sleep mode and a low pulsed tone is heard from the audible output You can reset the operator for a renewed 20 test cycles by turning the power off...

Page 15: ...rol board of the LP1000 operator See Figure 22 These lights are used to verify proper operation of the LP1000 TURN ON THE MAIN POWER SWITCH Remove the white high voltage connector from the control boa...

Page 16: ...lots in either direction to fine tune the gate s limits of travel When final adjustment has been completed insure that the detent plate is firmly seated in the slots Review Figure 18 Page 13 SETTING T...

Page 17: ...operator should respond to an obstruction not encountered by the other the gates will temporarily get out of sync Synchronization will be restored after the next input command cycle D STARTING THE OPE...

Page 18: ...to terminals 3 or 13 COMMON Multiple devices may be connected in parallel NAME DESCRIPTION 12 OPEN EDGE Momentary or continuous signal This input is active only when referenced to the opening directi...

Page 19: ...19 D STARTING THE OPERATOR Figure 23 Wiring Schematic and Diagram 110146...

Page 20: ...or Close Contact Sensor input or a Close Overload activation will cause the gate to stop pause and reverse for approximately 2 inches in the Open direction xIf the gate is moving in a Close direction...

Page 21: ...ollowing safety features x Electric gate edges x Enclosed tracks x Vertical guard posts x Protective screen mesh x Photoelectric sensors x Instructional and precautionary signs x Covers for exposed ro...

Page 22: ...mpensate for a poorly operating slide gate Correct all mechanical problems on the gate and gate hardware before installing the gate operator Have a qualified service technician make repairs to the gat...

Page 23: ...r 2 EA not shown 110136 Installation Owner s Manual 1 EA 24b 111886 Box Cover 4 x 2 Duplex Raised 1 EA OPERATOR EXPLODED VIEW 110153 OPERATOR PARTS LIST RISK OF ELECTROCUTION TURN OFF THE MAIN POWER S...

Page 24: ...purchase for multi family and commercial use To obtain service contact your dealer To obtain service under this warranty the buyer must obtain authorization instructions for the return of any goods f...

Reviews: