ALL POWER™ EPW2000 POWER WASHER | 15
OWNER’S MANUAL
| TROUBLESHOOTING
15
Problem
Probable Cause
Solution
When the switch is in the “I”
position the machine will not
start.
Electrical socket is faulty.
Check plug, socket and fuses.
Voltage is inadequate.
Check that the voltage is adequate.
GFCI trips.
Reset/Try another outlet.
Power cord is not plugged in.
Plug in power cord.
The pump does not reach
adequate pressure or
fluctuates.
Water Intake Filter is clogged
Remove and clean filter
Pump is drawing air
Tighten connections/bleed system
Suction valves are clogged/worn
Clean or replace valves
Diameter of garden hose too small
Replace with ¾ inch garden hose
Water supply is restricted
Check hose for kinks or leaks
Insufficient water supply
Fully open water source
The pressure washer has or
will not maintain pressure.
Excessive air in waterline and pump
Turn unit and water supply off / Bleed system / Hold trigger down
TROUBLESHOOTING GUIDE
The following troubleshooting guide is recommended for basic or
common problems; if there’s an issue with the generator that is not
listed,
please call 1-888-896-6881.
NOTE:
Troubleshooting problems may have similar causes
and
solutions.
Summary of Contents for EPW2000
Page 1: ...Electric Pressure Washer MODEL NO EPW2000 OWNER S MANUAL...
Page 17: ...ALL POWER EPW2000 POWER WASHER 17 OWNER S MANUAL NOTES 17 NOTES...
Page 20: ...20 ALL POWER EPW2000 POWER WASHER www allpoweramerica com 20 NOTES OWNER S MANUAL NOTES...
Page 21: ...ALL POWER EPW2000 POWER WASHER 21 OWNER S MANUAL NOTES 21 NOTES...
Page 24: ...2014 All Power America www allpoweramerica com...