Cleaning
The ionizing needle (emitter) must be cleaned at least every 14 days using a
dry lint free cloth
Risk of personal injury. The ionizing needle is pointed and sharp!
When cleaning the IONSTAR, the device must be disconnected from the
compressed air supply
9.
Troubleshooting
problem
cause
action necessary
No ionization
The ionization device is
soiled
Clean the IONSTAR
thoroughly
spark discharge (arc-over)
The ionization device is
soiled with conductive
particles, materials or fluids
Clean the IONSTAR
thoroughly
The ionizing needle
(emitter) is too close to a
conductive material
Increase the distance of the
IONSTAR to the electrically
conductive material which
is causing the problem
The ionization device is
damaged
Take the device out of
service immediately
Please note:
In case a fault or malfunction occurs, which cannot be rectified using
the measures described above, the unit can be sent to us, TOPLAC Autolackierbedarf
GmbH for inspection at the address below.