See the following table for a detailed description of each item.
UPS Setting
Item
Description
UPS Monitoring
Enable or disable UPS monitoring.
Manufacturer
Choose the UPS manufacturer from the dropdowns.
Model
Choose the UPS model number from the dropdowns.
Battery Status
Current status of the UPS battery
Power
Current status of the power being supplied to the UPS
Seconds between power failure and first
notification
Delay between power failure and first notification in
seconds.
Seconds between subsequent power
failure notifications
Delay between subsequent notifications in seconds.
Shutdown the system when the battery
charge is less than
Amount of UPS battery remaining before system should
auto-shutdown.
Apply
Press
Apply
to save your changes.
For a list of supported UPS units, see
Appendix E: UPS Compatibility List
.
Schedule Power On/Off
Using the ALL69000’s System Management, you can save energy and money by scheduling
the ALL69000 to turn itself on and off during certain times of the day.
From the menu, choose the
Schedule Power On/Off
item and the
Schedule Power On/Off
screen appears.
To designate a schedule for the ALL69000 to turn on and off, first enable the feature by
checking the
Enable Schedule Power On/Off
checkbox.
Then, simply choose an on and off time for each day of the week that you would like to
designate a schedule by using the various dropdowns.
Finally, click
Apply
to save your changes.