Allmatic CT INVERTER AM Manual For Installation Download Page 9

ITA 

 ENG   FRA   ESP   DEU   POR 

9 / 12 

6-1622595    rev.06     13/01/2017 

Compatible from 

firmware version 

CSMAM02

 

Enter the parameter 

Ped. Position 

of 

MENU 

and confirm by pressing 

key P2

 

 

Start moving the gate by pressing and releasing key P1 (START) or a 

Step-by-Step key. 

When the gate reaches the position of partial opening, then push key 

P1 (START) or a step-by-step key 

The gate moves again in closing. 

When the gate hits the limit in closing, then the programming is 

terminated. 

Exit the menu by scrolling the entries until you 

find EXIT 

 

6.2  Learning the partial run (Menu B –  Ped. Position

Learning the partial run allows to define the position of partial opening that allows the pedestrians accessing (PED command) 

Check that the adjustment of the torque and the speed of the gate are set before carrying out the learning phase. 

Check that the gate is closed before starting the learning phase. 

The entries of menu B - Speed and torque - once the parameters themselves are entered allow to adjust the corresponding parameters from a 

minimum up to a maximum value, according to the indications shown on the display. 

The versatility of the control board allows an infinity of possible combinations: however it is recommended  to adjust the settings by keeping into 

account the dimensions and weight of the gate. High speeds may be dangerous, as well as high torques. 

Such regulations must be carried out only by professionals. 

It is recommended to check the correct functioning of the automation after any regulation. 

It is highly recommended to learn the runs of the gate each time these parameters are changed. 

8.  Advanced functions 

Photocell test

 

 

This control unit is equipped with a function which allows to control the proper functioning of photocells before any operation of the motor is made. 

The  security  of  the  system  is  therefore  higher  in  case  the  photo-device  breaks  down  (for  example,  if  the  relay  of  exit  is  stuck)  or  there  is  a 

undesired short circuit on the input of the photocells. The control board indicates a possible fault by flashing only once when any key is pressed 

and also by not moving at all. This check is made after the control board receives a command to move, but before the control board itself gives 

power to the motor. 

Edge Test 

 

 

Functional test of the safety edge. Connect the safety edge as shown in the instructions by using the photocell test’s clamp. 

Condominium

 

 

All commands given via radio or by a step-by-step and/or a partial opening keys involve only the opening of the gate. The closing is related to the 

function of automatic closing, which 

MUST BE ABSOLUTELY ACTIVATED 

 since every command of closing is ignored. 

PhotoAutoReclose

 

 

The gate closes 3 seconds after the photocell intervenes in case the gate is in a totally open or in a partial open position. 

These are functions  and/or functional modalities that can be activated by the user through the programming menu. 

Automatic closing

 

 

Timed closing of the gate from totally open position or partial opening position. The “stop” command disables the automatic closing until a new 

command given by the user is received (

S.S., CLOSE

, etc). 

Motor brake

 

To  be  used  with  motors  with  a  strong  inertia  and  the  necessity  to  quickly  stop  the  automation.  Pay  attention  as  the  mechanics  must  be  sized 

accordingly. 

OFF:

 Brake disabled 

1: 

Electronic braking function  

2:

 Activation of the contact on the auxiliary card for an external brake, active with still motor 

3:

 Activation of the contact on the auxiliary card for an external brake, active when motor is moving 

Dead Man 

The motor moves only with permanent a command and not with just impulses: the motor opens if the key “open” is kept pressed, and the opposite 

operation applies with the key “close”. WARNING: this modality forbids all operations of automatic motion! 

Inv. On photocells

 

 

Allows to set if, once the photocell beam is interrupted, the gate must reverse immediately (only in closing) or just after the removal of the obstacle 

(it applies both in opening and in closing) 

Edge Inv.

 

 

Allows to set if, once the safety edge alarms itself, the gate must stop or it must stop and then reverse (applies only in the phase of closing)  

7  Adjustment of the speed and the torque (Menu B -  Speed and torque) 

Summary of Contents for CT INVERTER AM

Page 1: ...CT INVERTER AM CONTROL UNIT Programmable control board for sliding gates with inverter technology Manual for installation Compatible from firmware version CSMAM02...

Page 2: ...ngs It is also equipped with a molex connector for a plug in receiver output for courtesy and flashing light It is possible to connect an additional card R1 to operate an electric lock 1 Introduction...

Page 3: ...inputs if not used INPUT CLOSING LIMIT SWITCH Connect the contact NORMALLY CLOSED of the CLOSING LIMIT SWITCH L S CL between the clamps 3 and 8 of the control board Before activating the installation...

Page 4: ...sure that all the safey devices are correctly cabled and functioning refer to the preliminary checkings section of chap 4 Cable the motor WITHOUT using the capacitor ACCESSORIES OUTPUTS Accessories o...

Page 5: ...of manual accessing to the control board 4 Confirm the entry selected by pressing key P2 The first line of the display shows the present setting for the function selected The second line of the displa...

Page 6: ...hoto Test Functional test of the photocell it is executed before the gate moves OFF disabled ON test activated WARNING supply the photocell with power as shown in the scheme Edge Inv Modality of opera...

Page 7: ...of the wave supplied to the motor Low Speed CL Regulation of the speed of the gate during the closing phase when approaching the end of the run NNN speed expressed in Hz frequency of the wave supplie...

Page 8: ...gate closes then stop the manual motion disconnect the system from the power and reverse the motor connections Then try again If the gate opens then stop the manual motion and go to the following pha...

Page 9: ...cates a possible fault by flashing only once when any key is pressed and also by not moving at all This check is made after the control board receives a command to move but before the control board it...

Page 10: ...alue Encoder If the motor is equipped with a suitable encoder then it is possible to enable the functionalities of the encoder In such way the control board does not work any longer by time but with e...

Page 11: ...blinking Lower the torque supplied to the motor until problem is solved High Tor que OP High Torque OP Lower the speed of the motor until problem is solved High Speed OP High Speed CL 9 1 Low speed m...

Page 12: ...AX cos 0 8 Flashing light output 230 Vac 60W MAX for fixed light without self blinking Courtesy light output 230Vac 100W MAX Auxiliary output only with card R1 Clean contact out put NOT supplied 24Vac...