WARNING AND ADVICES 

Avoid putting the connection cables of buttons, security devices and inputs close to those of the power supply of the control unit and of the motor. Some 

parts of the control unit are subject to dangerous voltage. The control unit must be installed and programmed only by qualified professionals. Always use 

a device that ensures the disconnection of all poles of the control unit’s power supply . 

This device can be a switch (connected directly to the power supply terminals) with a contact’s minimum distance of 3 mm for each pole, or it can be a 

device connected to the power network. 

For connecting the card and the motors we recommend to use cables with double isolation as in compliance to the laws in force; the minimum cross 

section of the single conductor must not be less than 1,5 mm² and not more than 2.5mm². 

TECHNICAL FEATURES - CT INVERTER AM 

 

  

Power supply 

230 Vac +15%, -15% ;  50Hz 

Photocells power supply 

24 Vdc  3W MAX 

Accessories power supply 

24Vac 3W MAX  

Motor output 

230Vac 1,5KW (current limited to 10A) MAX cos

 > 0.8 

Flashing light output 

230 Vac 60W MAX for fixed light, without self-blinking. 

Courtesy light output 

230Vac 100W MAX 

Auxiliary output (only with card R1). Clean contact out-

put NOT supplied. 

24Vac 0.5A MAX (12W MAX) 

ALLMATIC S.r.l 

32020 Lentiai - Belluno – Italy 

Via dell’Artigiano, n°1 – Z.A. 

Tel. 0437 751175 – 751163 r.a.    Fax 0437 751065 

http://www.allmatic.com - E-mail: [email protected] 

GUARANTEE - In compliance with legislation, the manufacturer’s guarantee is valid from the date stamped on the product and is restricted to the re-

pair or free  replacement of the parts accepted by the manufacturer as being defective due to poor quality materials or manufacturing defects. The 

guarantee does not cover damage or defects caused by external agents, faulty maintenance, overloading, natural wear and tear, choice of incorrect 

product, assembly errors, or any other cause not imputable to the manufacturer. Products that have been misused will not be guaranteed or repaired.  

Printed specifications are only indicative. The manufacturer does not accept any responsibility for range reductions or malfunctions caused by environ-

mental interference. The manufacturer’s responsibility for damage caused to persons resulting from accidents of any nature caused by our defective 

products, are only those responsibilities that come under Italian law.

 

Summary of Contents for CT INVERTER AM

Page 1: ...CT INVERTER AM CONTROL UNIT Programmable control board for sliding gates with inverter technology Manual for installation Compatible from firmware version CSMAM02...

Page 2: ...ngs It is also equipped with a molex connector for a plug in receiver output for courtesy and flashing light It is possible to connect an additional card R1 to operate an electric lock 1 Introduction...

Page 3: ...inputs if not used INPUT CLOSING LIMIT SWITCH Connect the contact NORMALLY CLOSED of the CLOSING LIMIT SWITCH L S CL between the clamps 3 and 8 of the control board Before activating the installation...

Page 4: ...sure that all the safey devices are correctly cabled and functioning refer to the preliminary checkings section of chap 4 Cable the motor WITHOUT using the capacitor ACCESSORIES OUTPUTS Accessories o...

Page 5: ...of manual accessing to the control board 4 Confirm the entry selected by pressing key P2 The first line of the display shows the present setting for the function selected The second line of the displa...

Page 6: ...hoto Test Functional test of the photocell it is executed before the gate moves OFF disabled ON test activated WARNING supply the photocell with power as shown in the scheme Edge Inv Modality of opera...

Page 7: ...of the wave supplied to the motor Low Speed CL Regulation of the speed of the gate during the closing phase when approaching the end of the run NNN speed expressed in Hz frequency of the wave supplie...

Page 8: ...gate closes then stop the manual motion disconnect the system from the power and reverse the motor connections Then try again If the gate opens then stop the manual motion and go to the following pha...

Page 9: ...cates a possible fault by flashing only once when any key is pressed and also by not moving at all This check is made after the control board receives a command to move but before the control board it...

Page 10: ...alue Encoder If the motor is equipped with a suitable encoder then it is possible to enable the functionalities of the encoder In such way the control board does not work any longer by time but with e...

Page 11: ...blinking Lower the torque supplied to the motor until problem is solved High Tor que OP High Torque OP Lower the speed of the motor until problem is solved High Speed OP High Speed CL 9 1 Low speed m...

Page 12: ...AX cos 0 8 Flashing light output 230 Vac 60W MAX for fixed light without self blinking Courtesy light output 230Vac 100W MAX Auxiliary output only with card R1 Clean contact out put NOT supplied 24Vac...