Allmatic CT INVERTER AM Manual For Installation Download Page 10

ITA 

 ENG   FRA   ESP   DEU   POR 

10 / 12 

6-1622595    rev.06     13/01/2017 

Compatible from 

firmware version 

CSMAM02

 

Reset of the unit  according to the display indications; this reset the control board to its factory settings 

WARNING: all programming and personal settings must be repeated after the reset of the control board!  

Clock function 

 

Input 

OPEN

 becomes input 

clock

 in case it is possible to connect a timer for the programmed opening of the automation. The contact is 

understood as a command to opening and to stay open as long as this status stays closed. When the contact is opened, then the unit reset its 

normal functioning, waiting for a command given by the user (if the automatic closing is required, then it must be enabled from the menu). 

Pre-flashing

 

 

This function commands a blinking BEFORE each movement in order to indicate the imminent movement itself.  

Zone light

 

 

There is the possibility to use the auxiliary output as a courtesy light or as a light zone (always lit-on as long as the gate is open) 

Auxiliary light timeout

 

 

There is the possibility to set the delay of switching-off of the auxiliary light after the automation stops 

Water hammer in opening

 

If the automation is equipped with an electronic lock, then it is advisable that, when the gate is closed, the motor shortly operates in closing before 

it starts the opening phase (water hammer). This function allows to unlock the electronic lock in any case, even when the weather conditions are 

very bad (for example in case of ice). The activation of this function enables also the electronic lock’s output. 

Sensor level 

If it is enabled, it allows to modify the intervention sensitivity of the “stop motor” sensor. Decrease the value that is set in order to have higher 

sensitivity. If the sensitivity is too high and the sensor operates without any apparent reason, then increase the value.

 

 

Encoder

 

 

If the motor is equipped with a suitable encoder, then it is possible to enable the functionalities of the encoder. In such way the control board does 

not work any longer “by time” but “with encoder” instead. It is possible to detect the possible blocking of the motor. 

Sensor inversion

 

 

Allows to define the reaction of the gate in case the “stop motor” sensor applies. If the reversing is not activated, then the gate stops and waits for 

a new command. If the reversing is activated, then the gate reverses shortly in case the sensor applies during the opening; it open completely in 

case the sensor applies during the closing phase of the gate. 

10 Backlighting of the display (Menu C -  Display light) 

Enter 

MENU C 

and follow the instructions shown on the display in order to enable/disable the backlighting of the display itself.  

The control board operates the function Energy saving which automatically switches off the display after the unit is inactive since some minutes. 

The backlighting is automatically reactivated (if this function is enabled) when the user operates on the control board. 

11 Housing for radio receiver 

The unit disposes of a molex connector to house an ALLMATIC radio receiver. The first channel of the receiver is associated to the wired com-

mand 

S.S.

, whereas the second radio-channel (if it is present) is associated to wired command 

PED

Follow the instructions of the receiver itself for learning the transmitters. 

The functioning of the additional card depends on the setting of the parameter “Brake”: 

Parameter “Brake” OFF-1: 

A normally open contact is available on the output for the activation of the electronic lock. The electronic lock can be acti-

vated by previously enabling the Water Hammer in opening (

parameter Water Hammer OP)

Parameter “Brake” 2-3: 

A contact is available on the output for the activation of an external brake. 

9 RESET of the control board (Menu C -  Reset) 

12 Auxiliary output (this output is available only with the additional card R1) 

ELECTRICAL LOCK, 

MOTOR BRAKE 

Connection 

with the  

control unit 

Summary of Contents for CT INVERTER AM

Page 1: ...CT INVERTER AM CONTROL UNIT Programmable control board for sliding gates with inverter technology Manual for installation Compatible from firmware version CSMAM02...

Page 2: ...ngs It is also equipped with a molex connector for a plug in receiver output for courtesy and flashing light It is possible to connect an additional card R1 to operate an electric lock 1 Introduction...

Page 3: ...inputs if not used INPUT CLOSING LIMIT SWITCH Connect the contact NORMALLY CLOSED of the CLOSING LIMIT SWITCH L S CL between the clamps 3 and 8 of the control board Before activating the installation...

Page 4: ...sure that all the safey devices are correctly cabled and functioning refer to the preliminary checkings section of chap 4 Cable the motor WITHOUT using the capacitor ACCESSORIES OUTPUTS Accessories o...

Page 5: ...of manual accessing to the control board 4 Confirm the entry selected by pressing key P2 The first line of the display shows the present setting for the function selected The second line of the displa...

Page 6: ...hoto Test Functional test of the photocell it is executed before the gate moves OFF disabled ON test activated WARNING supply the photocell with power as shown in the scheme Edge Inv Modality of opera...

Page 7: ...of the wave supplied to the motor Low Speed CL Regulation of the speed of the gate during the closing phase when approaching the end of the run NNN speed expressed in Hz frequency of the wave supplie...

Page 8: ...gate closes then stop the manual motion disconnect the system from the power and reverse the motor connections Then try again If the gate opens then stop the manual motion and go to the following pha...

Page 9: ...cates a possible fault by flashing only once when any key is pressed and also by not moving at all This check is made after the control board receives a command to move but before the control board it...

Page 10: ...alue Encoder If the motor is equipped with a suitable encoder then it is possible to enable the functionalities of the encoder In such way the control board does not work any longer by time but with e...

Page 11: ...blinking Lower the torque supplied to the motor until problem is solved High Tor que OP High Torque OP Lower the speed of the motor until problem is solved High Speed OP High Speed CL 9 1 Low speed m...

Page 12: ...AX cos 0 8 Flashing light output 230 Vac 60W MAX for fixed light without self blinking Courtesy light output 230Vac 100W MAX Auxiliary output only with card R1 Clean contact out put NOT supplied 24Vac...