Allied Construction Products, LLC Technical Manual Ho-Pac 300, 300B & 500, 500B
7
Static Relief Pressure
– Also referred to as
“Full Relief Pressure”. The pressure
measured at the moment the relief valve
has opened fully and all oil is by-passed.
Opening Curve
– The dynamic pressure is
always less than the static pressure. A relief
valve adjusted to a dynamic pressure of
3000 psi (200 Bar) will crack open when the
preset point is reached, but fully opens at a
higher pressure. The opening curve is the
rise of pressure between dynamic and
static.
IMPORTANT
The carrier's hydraulic system shall be
capable of providing the desired oil flow at
a pressure equal to at least the dynamic
relief pressure.
FLOW
PRESSURE
Hydraulic
Flow Range
Operating
Pressure
Range
Static Relief Pressure
(No flow to attachment)
Dynamic Relief Pressure
(Relief valve cracks open)
Attachment
Operational
Range
Operating Pressure
Opening
Curve
Fig. 4-1
Flow-Pressure Diagram
Summary of Contents for 300