Camera interfaces
Triggering during the Readout State
For applications requiring the fastest triggering cycle time whereby the camera
image sensor is exposing and reading out simultaneously, then the User trigger
signal should be applied as soon as a valid trigger Ready is detected.
In this case, trigger Latency and trigger jitter can be up to 1 line time since
exposure must always begin on an Interline boundary.
www
For a more detailed description of the trigger concept for
advanced users
and special scenarios, see: