Example:
To set exposure time the value
you want is entered into the
Extended shutter register
Set number of frames
in Seq_Length
ImageNo = 0
ApplyParameters = 1
Assign image
properties in
corresponding
registers
Repeat steps 4 to 6
Increase
ImageNo
on/off
to "true"
Start sequence in
MultiShot or
ISOEnable mode
Figure 31 Sequence mode
During this process the camera gets the required parameters image by image from the
corresponding FIFOs (e.g. information for exposure time)
L
The appearance of the images is based on the data from the FIFOs. This also applies
when less sensible, invalid or no data at all are stored in memory.
L
If more images are recorded than data sets are stored in the sequence, the last
parameters are applied to all additional images.