20
Max. collector voltage
500 mA
Max. collector emitter voltage
45 V
L
Depending on the voltage applied a resistor may have to be switched in series
(see diagram). Voltage above 45 V can damage the circuit.
Output features are configured by software.
Any signal can be placed on any output.
The main features of output signals are described below:
IntEna Signal
This signal displays the time the exposure was made. By using a register this output can
be delayed by up to 1.05 seconds (see Enabling delayed integration).
Fval Signal
This feature signals readout from the sensor. This signal Fval follows IntEna.
Busy Signal
This indicator appears when the exposure is being made, the sensor is being read from
or data transmission is active. The camera is busy.
Please refer to the following impulse diagram for information on how the individual
signals are dependent on one another:
Figure 17 Impulse diagram
It is possible to use the IO_OUTP_CTRL1...3 register (see IO_OUTP_CTRL1) to assign a
function to each output.
IntEna
Output
Polarity
FVal
Output Signal
Ouput
Function
Busy
Ouput
State
Opto-
koppler
Figure 18 Camera outputs