Chapter 1: Overview
34
Figure 18. Example of an Invalid Configuration - A
In the example in Figure 19 on page 35, the power supply in slot A is
supporting a low-power switch and a high-power switch. This configuration
is invalid because the power supply modules can support only one switch
if it is a high-power switch. You could resolve the problem by installing a
power supply module in slot B and connecting one of the switches to RPS
port 3 or 4. The resolution is shown in Figure 11 on page 28.