4.

Slide the new AT-PWR11 power supply into the power supply slot until it makes 
contact with the backplane of the chassis. Be sure that the labeling on the 
power supply is right-side up. Also be sure to align the green board on the 
power supply with the slots in the chassis. Once the power supply makes 
contact with its connector on the backplane, press firmly to fully seat the power 
supply on the power connector.

Note

If you are unable to slide the power supply completely into the slot, you may 
have purchased the wrong type of power supply for the chassis. A DC 
powered chassis will have two DC terminal blocks on the back panel.

5.

Move the locking levers on the AT-PWR11 unit into the locked position and 
tighten the captive screw to secure the power supply in the chassis.

Note

Always use the installation screw to secure the power supply to the switch. 
Leaving the power supply partially seated may cause the system to halt and 
subsequently crash. 

6.

Slide the power supply cover back into the chassis and secure the cover by 
tightening the two captive screws.

AT-PW

R11

DC

P

O

W
E
R

F

A
U
L
T

1

AT-84

11

TX

EJECT

LNK
10

ACT
100

2

3

AT-84

11

TX

EJECT

LNK
10

ACT
100

AT-84

11

TX

EJECT

LNK
10

ACT
100

AT-PW

R11

DC

P

O

W
E
R

F

A
U
L
T

WARN

ING

BEFOR

E

EJECTING

,

LOOSEN

THU

MBSC

REW

!

AT-PW

R11

DC

P

O

W
E
R

F

A
U
L
T

AT-PW

R11

DC

P

O

W
E
R

F

A
U
L
T

WARNING

BEFO

RE

EJECTING,

LOO

SEN

THUM

BSCREW

!

WARNING

BEFO

RE

EJEC

TING,

LOOSE

N

THU

MBSCREW

!

Wiring the AT-PWR11 Power Supply

Warning

ALWAYS

 connect the wiring to the LAN equipment first before connecting 

the wiring to the breaker. To avoid the danger of physical injury from 
electrical shock, do not work with HOT feeds. Always be sure that the breaker 
is in the OFF position before connecting the wiring to the breaker.

Note

A tray cable is required to connect the power source if the unit is powered by 
centralized DC power. The tray cable must be UL listed Type TC tray cable and 
rated at 600 V and 90 degree C, with three conductors, minimum 14 AWG.

1.

On the rear side of the chassis is a DC terminal block labeled POWER B. Starting 
from the left side of the terminal block, identify the 

positive

frame ground

 

and 

negative

 terminals using the symbols beneath to the terminal block.

2.

With a 14-gauge wire-stripping tool, strip the three wires in the tray cable 

coming from the DC input power source to 8mm 

±

 1mm (0.31 in., 

±

 0.039 in.).

Warning

Do not strip more than the recommended amount of wire. Stripping more 
than the recommended amount can create a safety hazard by leaving 
exposed wire on the terminal block after installation.

3.

Connect the frame ground wire to the terminal marked with the ground 
symbol by inserting the wire into the terminal and tightening the connection 
with a flathead screwdriver. 

Warning

When installing this equipment, always ensure that the frame ground 
connection is installed first and disconnected last.

4.

Connect the -48 VDC RTN feed wire to the terminal block  (plus).

5.

Connect the -48 VDC feed wire to the terminal block marked - (minus).

8mm 

±

1mm

(0.31in. 

±

0.039 in.)

40-60VDC

Warning

"Safety Hazard"

- Check to see if there are any exposed copper strands 

coming from the installed wires. When this installation is done correctly 
there should be no exposed copper wire strands extending from the 
terminal block. Any exposed wiring can conduct harmful levels of electricity 
to persons touching the wires.

6.

Secure the tray supply cable near the rack framework using multiple cable ties 
to minimize the chance of the connections being disturbed by casual contact 
with the wiring. Use at least four cable ties, separated four inches apart. Locate 
the first one within six inches of the terminal block.

Note

This system will work with a positive grounded or negative grounded DC 
system.

7.

Ensure that the circuit breaker is in the OFF position.

8.

Connect the supply-cable wires to the circuit breaker.

9.

Energize the circuit breaker.

Technical Specifications

Power Specifications:

40 - 60V DC, 6A maximum

Maximum Operating Temperature:

0° C to 40° C (32° F to 104° F)

Maximum Storage Temperature:

-20° C to 80° C (-4° F to 176° F)

Operating and Storage Altitude:

Up to 3,048 meters (10,000 feet)

Relative Humidity Operating
and Storage:

5% to 80% (non-condensing)

Electrical Safety and Emission Statement

Standards

: This product meets the following standards when installed in compliant host equipment.

Emission

FCC Class A, EN55022 Class A, EN61000-3-2, EN61000-3-3, VCCI Class A, C-TICK

WARNING

In a domestic environment this product may cause radio interference in which case the user may be 
required to take adequate measures. 

Immunity

EN55024

Electrical Safety

UL60950 (UL/cUL), EN60950 (TUV)

Copyright 

 

2003 Allied Telesyn, Inc. All rights reserved. 

No part of this publication may be reproduced without prior written permission from Allied Telesyn Inc.

U.S. Federal Communications Commission 

RADIATED ENERGY
Note: This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to 
Part 15 of FCC Rules. These limits are designed to provide reasonable protection against harmful interference when 
the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio 
frequency energy and, if not installed and used in accordance with this instruction manual, may cause harmful 
interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful 
interference in which case the user will be required to correct the interference at his own expense.

Note: Modifications or changes not expressly approved of by the manufacturer or the FCC, can void your right to 
operate this equipment.

Industry Canada

This Class A digital apparatus meets all requirements of the Canadian Interference-Causing Equipment Regulations.

Cet appareil numérique de la classe A respecte toutes les exigences du Règlement sur le matériel brouilleur du 
Canada.

4