Chapter 3: Powering On the Media Converter
43
3. With a 14-gauge wire-stripping tool, strip the two wires in the tray cable
coming from the DC input power source to 8 millimeters ± 1 millimeters
(0.31 inches ± 0.039 inches), as shown in Figure 23.
Warning
Do not strip more than the recommended amount of wire. Stripping
more than the recommended amount can create a safety hazard by
leaving exposed wire on the terminal block after installation.
E10
Figure 23. Stripped Wire
4. Connect the negative feed wire to the terminal marked
V-
(
negative
)
by inserting the wire into the terminal block and tightening the
connection with a flathead screwdriver. SeeFigure 24.
Figure 24. Connecting the Feed Wire
5. Connect the positive feed wire to the terminal block marked
V+
(
positive
).
Warning
Check to see if there are any exposed copper strands coming from
the installed wire. When this installation is done correctly there
should be no exposed copper wire strands extending from the
terminal block. Any exposed wiring can conduct harmful levels of
electricity to persons touching the wires.
E12
8mm ±1mm
(0.31in. ±0.039in.)