170 Series Tumble Dryer Models
Serial Plate Rat-
ing
Terminal Block
Connections Re-
quired
Rated Current*
(amps)
Breaker Rating
Recommended
Wire Size AWG
[mm²]
200-208/240V/
60Hz/3ph
L1,L2,L3 and ground
13.5
20A - 3 pole
12 [4]
380V/50 or 60Hz/3ph
L1,L2,L3 and ground
6.9
15A - 3 pole
14 [2.5]
400-415V/50Hz/3ph
L1,L2,L3 and ground
6.9
15A - 3 pole
14 [2.5]
440V/60Hz/3ph
L1,L2,L3 and ground
6.4
15A - 3 pole
14 [2.5]
460-480V/60Hz/3ph
L1,L2,L3 and ground
6.7
15A - 3 pole
14 [2.5]
* Current ratings vary slightly depending on model; refer to serial plate.
200 Series Tumble Dryer Models
Serial Plate Rat-
ing
Terminal Block
Connections Re-
quired
Rated Current*
(amps)
Breaker Rating
Recommended
Wire Size AWG
[mm²]
200-208/240V/
60Hz/3ph
L1, L2, L3 and ground
14
20A - 3 pole
12 [ 4]
380V/50Hz/3ph
L1, L2, L3 and ground
8
15A - 3 pole
14 [2.5]
400-415V/50Hz/3ph
L1, L2, L3 and ground
8
15A - 3 pole
14 [2.5]
440V/60Hz/3ph
L1, L2, L3 and ground
7
15A - 3 pole
14 [2.5]
460-480V/60Hz/3ph
L1, L2, L3 and ground
7
15A - 3 pole
14 [2.5]
* Current ratings vary slightly depending on model; refer to serial plate.
Electrical Requirements
©
Copyright, Alliance Laundry Systems LLC -
DO NOT COPY or TRANSMIT
58
Part No. 70458101ENR10
Summary of Contents for XT170L
Page 2: ......