Electrical Specifications
NOTE: Minimum wire sizes are obtained from Canadian
Electrical Code and are intended for use as a guideline
only. Electrical connections should be made only by a
qualified electrical contractor in accordance with all ap-
plicable local and national requirements.
NOTE: Electrical specifications below are subject to
change without notice. Always refer to product serial
plate for most current specifications of product being
installed.
NOTE: Use copper conductors only.
NOTE: Connect to individual branch circuit.
NOTE: 3 Phase Only – Each tumble dryer must be con-
nected to its own individual branch circuit breaker, not
fuses, to avoid the possibility of “single phasing” and
causing premature failure of the motor(s).
120 Series Gas and Steam Tumble Dryer Models
Serial Plate Rat-
ing
Terminal Block
Connections Re-
quired
Rated Current*
(amps)
Breaker Rating
Recommended
Wire Size AWG
[mm²]
200-208/240V/
60Hz/3ph
L1,L2,L3 and ground
7.7
15A - 3 pole
14 [2.5]
230V/50Hz/3ph
L1,L2,L3 and ground
7.3
15A - 3 pole
14 [2.5]
380V/50 or 60Hz/3ph
L1,L2,L3 and ground
4.1
10A - 3 pole
14 [2.5]
400-415V/50Hz/3ph
L1,L2,L3 and ground
3.8
10A - 3 pole
14 [2.5]
440V/60Hz/3ph
L1,L2,L3 and ground
3.8
10A - 3 pole
14 [2.5]
460-480V/60Hz/3ph
L1,L2,L3 and ground
3.9
10A - 3 pole
14 [2.5]
* Current ratings vary slightly depending on model; refer to serial plate.
120 Series Electric Tumble Dryer Models
Serial Plate Rat-
ing
Terminal Block
Connections Re-
quired
Rated Current*
(amps)
Breaker Rating
Recommended
Wire Size AWG
[mm²]
240V/60Hz/3ph
L1,L2,L3 and ground
152
175A - 3 pole
3/0 [95]
380V/50 or 60Hz/3ph
L1,L2,L3 and ground
94.5
125A - 3 pole
1 [35]
400-415V/50Hz/3ph
L1,L2,L3 and ground
87
125A - 3 pole
1 [35]
480V/60Hz/3ph
L1,L2,L3 and ground
76.1
100A - 3 pole
3 [26.2]
* Current ratings vary slightly depending on model; refer to serial plate.
Electrical Requirements
©
Copyright, Alliance Laundry Systems LLC -
DO NOT COPY or TRANSMIT
57
Part No. 70458101ENR10