pop-rivets on all seams and joints is recommended, if allowed by
local codes.
Verify that old ducts are thoroughly cleaned out before installing
new tumble dryer(s).
WARNING
Improperly sized or assembled ductwork causes ex-
cess back pressure which results in slow drying, lint
collecting in the duct, lint blowing back into the
room, and increased fire hazard.
W355
NOTE: Exhaust ducts must be constructed of sheet
metal or other noncombustible material. Such ducts
must be equivalent in strength and corrosion resist-
ance to ducts made of galvanized sheet steel not less
than 0.0195 inches [0.495 mm] thick.
Where the exhaust duct pierces a combustible wall or ceiling, the
opening must be sized per local codes. The space around the duct
may be sealed with noncombustible material. Refer to
Figure 10
.
IMPORTANT: For best performance provide an individ-
ual exhaust duct for each tumble dryer. Do not install a
hot water heater in a room containing tumble dryers. It
is better to have the water heater in a separate room
with a separate air inlet.
TMB2361N_SVG
5
4
3
2
1
TMB2362N_SVG
5
4
3
2
1
TMB2426N_SVG
5
4
3
2
1
1.
Removable strip of panel in framing wall to permit removal of tumble dryer from framing wall
2.
Partition or bulkhead
3.
Minimum distance between exhaust opening and roof, ground or other obstruction: 36 in. [914 mm]
4.
2 in. [51 mm] minimum clearance on both sides of duct
5.
Exhaust airflow – maximum length of rigid duct 14 ft. [4.3 m] or 7.87 ft. [2.4 m] of flexible metal duct
Figure 10
NOTE: Do not install wire mesh or screen in exhaust
duct opening to avoid lint build-up or impacting proper
discharge of air from tumble dryers.
NOTE: Where exhaust duct pierces a combustible wall
or ceiling, the opening must be sized per local codes.
NOTE: Inside of duct must be smooth. Do not use
sheet metal screws to join sections.
NOTE: Locate exhaust far enough away from make-up
air location to prevent re-introduction.
Consult your local building code for regulations which may also
apply.
Alternate Venting for 120 Series Tumble Dryers
The 120 series tumble dryer is equipped from the factory to exhaust from the top; however, it may be converted to exhaust out the rear
by doing the following (refer to Specifications and Dimensions section):
1.
Remove belt guard cover.
2.
Remove 10 inch [254 mm] diameter elbow and vertical duct.
Exhaust Requirements
©