
country sticker (included with machine) and apply it to the serial
plate over the existing country information.
These instructions are only valid if the following country code is
on the appliance: GB/IE/PT/ES/IT/GR/LU/CH/BE. If this code is
not present on the appliance, it is necessary to refer to the techni-
cal instructions which will provide the necessary information
concerning the modification of the appliance to the condition of
use for the country.
Before installation, check that the local distribution conditions,
nature of gas and pressure, and the adjustment of the appliance
are compatible.
Table 1
describes the different gases that are available in different
CE countries, and how the machines need to be configured to op-
erate with those gases. In the CE, there are Natural Gas configu-
rations that do not allow for machine regulation and L.P. Gas
configurations that must be regulated. For L.P. Gas, third family
B/P at 50 mbar (5 kPa), order Regulated Natural Gas machines
and convert according to
Table 1
.
CE Orifices
Gas
Type
Gas
Fam-
ily
Grou
p
Gas
Desig-
nation
Supply
Pressure
in. wc
[mbar,
kPa]
Manifold
Pressure
in. wc
[mbar,
kPa]
Capaci-
ty/
Model
Orifice
Diam-
eter
inch
[mm]
Orifice
Part
Num-
ber
Quanti-
ty
Natural
Gas
Second
I
2H(E)
G20
8/10 [20/25,
2/2.5]
3.57 [8.9,
0.89]
120
0.1695
[4.3]
M402988
3
170
0.1850
[4.7]
M411510
4
200
0.1890
[4.8]
M411372
4
I
2L
G25
10 [25, 2.5]
5.06 [12.6,
1.26]
120
0.1695
[4.3]
M411373
3
170
0.1850
[4.7]
M411510
4
200
0.1890
[4.8]
M411372
4
I
2E+
G20
8 [20, 2.0]
Unregulated
120
0.1417
[3.6]
M401014
3
170
0.1496
[3.8]
M402997
4
200
0.1520
[3.9]
M401020
4
Table 1
continues...
Installation
©
Copyright, Alliance Laundry Systems LLC -
DO NOT COPY or TRANSMIT
31
Part No. 70458101ENR10
Summary of Contents for XT170L
Page 2: ......