116
801803
Section 7 Dryer Test Procedures
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect all electric power to the machine and accessories before servicing.
• Close gas shut-off valve to gas dryer before servicing.
• Never start machine with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the machine is properly grounded.
• Washer motor not grounded! Disconnect electric power before servicing motor.
W502
WARNING
89. MOTOR SWITCH
a. Remove motor and exhaust fan assembly. Refer
b. Remove the two motor switch attaching screws.
Refer to Figure 71. Disconnect switch leads.
Remove motor switch.
c. Remove thermal overload protector
NOTE: The thermal overload protector is unique to
the motor from which it was removed and should
only be used on that motor. To reduce the risk of
overheating the motor, do not use any thermal
overload protector other than the one taken from
the inoperative motor switch in step 3.
(1) Motor with Switch on Blower End
Using a small bladed screwdriver, press the
thermal overload protector mounting tab
downward and remove the thermal
overload protector from the inoperative
motor switch. Figure 66.
Figure 66
D029KE3A
Mounting
Tab
Thermal
Overload
Protector
Motor
Switch