46
512176
Section 5 Service Procedures
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the dryer(s) before servicing.
• Close gas shut-off valve to gas dryer(s) before servicing.
• Never start the dryer(s) with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the dryer is properly grounded.
W001R1
WARNING
l.
Motor pulley and idler pulley assemblies.
for motor and idler pulley
removal.
NOTE: When repairing or replacing the idler lever,
it is important to make sure the idler lever moves
freely. To ensure that the idler lever can move
freely, proceed as follows:
(1) Unhook idler spring.
(2) Lift idler lever approximately 3 inches and
release. If idler lever does not fall back to
the base of the motor mount, then idler
lever bolt is too tight.
(3) Loosen idler lever bolt 1/4 turn.
(4) Add grease between idler lever and motor
mount.
m.
Blower fan and housing.
(1) Remove screws holding cover to housing.
.
(2) Hold motor pulley securely and unthread
blower fan from motor shaft (right hand
thread). Use a 7/8 inch, 6 point socket to aid
in the removal of the blower fan.
(3) Remove three screws holding the blower
housing to the motor mounting bracket.
Refer to
.
n.
Motor.
(1) Disengage motor wire harness terminal
block from the motor by pressing in on the
movable locking tabs (located on each side
of the terminal block) and pulling away
from motor. Refer to
IMPORTANT: To avoid an open circuit, DO NOT
pull on the terminal block wires when removing
blocks from motor as this could damage the wires or
terminal crimping.
Before attaching wire harness terminal block to
motor, be sure all the male terminals on motor are
straight and are capable of accepting the terminals
from the wire harness terminal block
.
(2) Pry two motor clamps off motor mounting
bracket with screwdriver, then lift motor
out of mounting bracket. Refer to
.
Figure 28
Blower Housing
Attaching Screws
D249SE3B
Figure 29
Locking
Tabs
Motor
Wire Harness
Connection Block
D250SE3A
Summary of Contents for AES17AWF