Exhaust System
For best drying results, recommended maximum length of ex-
haust system is shown in
Table 2
.
To prevent backdraft when dryer is not in operation, outer end of
exhaust pipe must have a weather hood with hinged dampers (ob-
tain locally).
NOTE: Weather hood should be installed at least 305
mm [12 inches] above the ground. Larger clearances
may be necessary for installations where heavy snow-
fall can occur.
Number of 90° Elbows
Weather Hood Type
Recommended
Use Only for Short Run Installations
D673I_SVG
1
1
1. 102 mm [4 in.]
D802I_SVG
1
1. 64 mm [2.5 in.]
Maximum length of 102 mm [4 in.] diameter rigid metal duct.
0
19.8 m [65 feet]
16.8 m [55 feet]
1
16.8 m [55 feet]
14.3 m [47 feet]
2
14.3 m [47 feet]
12.5 m [41 feet]
3
11.0 m [36 feet]
9.1 m [30 feet]
4
8.5 m [28 feet]
6.7 m [22 feet]
Table 2
NOTE: Deduct 1.8 m [6 feet] for each additional elbow.
NOTE: The maximum length of a 102 mm [4 in.] diame-
ter flexible metal duct must not exceed 2.4 m [7.87 ft.].
Gas Dryers - Connect Gas Supply Pipe
NOTE: The gas service to a gas dryer must conform
with the local codes and ordinances and in Australia
and New Zealand, installation must comply with the
Gas Installations Standard AS/ NZS 5601 Part 1: Gener-
al Installations. In the absence of local codes and ordi-
nances, applicable National codes should be followed.
1. Install the dryer with sufficient clearance for adequate air cir-
culation, and for the ease of the dryer installation, servicing
and operation. For maximum drying performance, we recom-
mend you allow more clearance than the clearances that are
listed throughout this manual.
2. Remove the shipping cap from the gas connection at the rear
of the dryer. Make sure you do not damage the pipe threads
when removing the cap.
NOTE: If gas supply connection is British Standard
Pipe Tapered thread (BSPT), order 44178804 brass
female NPT (FPT) to male BSPT gas pipe thread
adapter, available at extra cost.
3. Make certain your dryer is equipped for use with the type of
gas in your laundry room.
NOTE: Natural gas, 37.3 MJ/m
3
[1000 Btu/ft
3
], serv-
ice must be supplied at 1.13 kPa [4.54 inch]water
column pressure. Do not connect the dryer to L.P.
(Liquefied Petroleum) gas service without convert-
ing the gas valve. A No. 401P3 L.P. Gas Conversion
Kit must be installed by the Manufacturer’s Author-
ized Dealers, Distributors, or local service person-
nel.
Installation
©
Copyright, Alliance Laundry Systems LLC -
DO NOT COPY or TRANSMIT
12
Part No. D516105R2