ID
Alarm Text
OMS
Ceasing
Alarm Unit Alarm Level
Description
55
R2R queue full
No
BSC
None
The R2R transmitting queue is full and messages are lost.
Suggested remedy: Check the R2R configuration and cables.
56
R2R node lost
No
BSC
None
An R2R node is lost.
Suggested remedy: Check if the node is still operating and
connected.
57
R2R HW error
No
BSC
Error
R2R hardware fault.
Suggested remedy: Replace the repeater.
70
Bad table found
No
BSC
Error
A requested table contains information error (software error).
71
Table not found
No
BSC
Error
A requested table was not found in the database (software or
calibration error).
72
Table database
err
No
BSC
Error
The database table is not found (calibration error).
121
Synthesizer fault
Yes
BSC UL/DL
Error
Unlocked synthesizer.
The frequency synthesizer is unlocked and the transmission can
take place on unknown frequency.
122
Volt Reg fault
Yes
BSC UL/DL
Error
A DC voltage to an analog part of the board is missing.
123
PA fault
Yes
BSC UL/DL
Error
Low power amplifier gain.
The PA has too low output power for the RSSI and gain set.
Not available in all BSC software versions.
125
High temperature
No
BSC UL/DL
Warning
The BSC board temperature is higher than 85°C.
Error
The BSC board temperature is higher than 95°C and the power
is turned off.
Ceasing
The temperature has fallen to below 70°C and the power is
turned on again.
126
High PSU
voltage
Yes
BSC UL/DL
Critical
The PA supply voltage is too high.
Suggested remedy: Ensure that correct PSM is used.
Remarks
The
Mains breakdown alarm (3) requires a relay not included in the repeater.
The
Door open alarm (20) requires an optional door switch.
The
Battery backup fault alarm (48) requires an optional battery backup unit.
The