Allflex AWR300 User Guide
13/11/19
Page 32
6.5.1.4
Wireless Sync On/Off
ISO11784/11785 RFID readers have activation and listening periods. If two or more readers
operate in close vicinity, they must be synchronized to prevent interference and hence a
reduction of reading performance, especially for HDX transponders.
Since it is not possible to synchronize mobile readers wired in the field, Allflex readers offer a
feature called ‘
Wireless Synchronization
’. This function enables mobile devices to operate
close to stationary readers without interfering with them. In addition, several mobile readers
can synchronize wirelessly.
If you have other ISO11784/11785 readers operating close to the AWR300, it is highly
recommended to activate this function.
Screen
Details
Select the desired setting using the / / / keys and
confirm with .
6.5.1.5
Volume and Vibrator
The AWR300 provides a speaker and a vibrating handle for alerts, in addition to the LEDs and
the display. These can be configured in this menu:
Screen
Details
After selecting ‘Volume & Vibrator’, a new menu is shown.
•
The first menu item sets the speaker volume.
•
The second is used to activate the vibrating motor in the
handle or to deactivate it.
Select the desired volume by using the / keys. Each time
a key is pressed, a sound is played to indicate the currently
selected volume.
Confirm the selected volume with .
If stationary readers are used, the Wireless Synchronization works best when
all the equipment is Allflex. This is because
Allflex
S
tationary
R
eaders (ASR)
also offer Wireless Synchronization and fixed timings, which allow for the
best possible performance for wirelessly synchronized mobile readers.