Allflex AWR300 User Guide
13/11/19
Page 30
The display also looks different after reading a transponder,
depending on how this setting is configured:
When the Animal Counter is not activated, the current
group and the number of records in this group is shown but
the records can also include duplicate EIDs.
When the Animal Counter is activated, the display shows
‘Animals’ instead of ‘Records’ – duplicates are not possible
here.
6.5.1.2
Set Read Mode
By default, the AWR300 is configured to ‘
Single Read
’. This means that RFID is activated until
a transponder has been detected or the ‘
Single Read Time
’ (default = 10 seconds) has elapsed.
The key has to be pressed to scan for tags again.
The AWR300 also allows using the ‘
Continuous Read
’ mode. The RFID engine will not be de-
activated after a tag has been read. It continues scanning until the ‘
Continuous Read
Time
’
(default = 60 seconds) has elapsed. Every new tag read resets this timeout.