Rockwell Automation Publication 7000-UM203C-EN-P - September 2018
39
Appendix
B
Spare Parts and Preventative Maintenance
Spare Parts
The estimated time required to verify if the functional safety system in the
drive is functioning is less than 0.5 hours.
Preventative Maintenance
Replace the following parts at 12 year intervals to maintain the SIL rating of
the drive.
Part No.
Description
Quantity
PN-504125
Optical Interface Base Board Safety (OIBBS)
1
PN-271938
Optical Interface Board (OIB2)
1
PN-35744
Safety Industrial Relay
1
440R-N23132
Safety Relay
1
1606-XLP50E
XLP 50 W Power Supply
1
ATTENTION:
In addition to the restart procedure in the user manual, perform
the Verify Operation procedures on
page 23
after replacing any of these
components.
IMPORTANT
See the PowerFlex™ 7000 user manual for detailed preventative
maintenance schedule and procedure for other non-safety related parts.
Part
Quantity
OIBBS
2
OIB2
2/4/6 (based on voltage class)
SGCTs
12/24/36 (based on voltage class)
MSR127 1
Summary of Contents for PowerFlex 7000 Series