Rockwell Automation Publication 20P-TG001C-EN-P - February 2018
77
Part Replacement Procedures
Chapter 3
Total Resistance Values
Table 16 - 230V AC Input Drives
Table 17 - 460V AC Input Drives
3. Seal the TA potentiometer in place using RTV (silicon).
4. Continue with Install the Configured Pulse Transformer Circuit Board
and the Switching Power Supply Circuit Boards on page
.
Drive Current
Rating Code
DC
Amps
AC Line
Amps
Hp
Set RTA Value Using TA
Potentiometer (Ohms)
7P0
7
5.7
1.5
34.971
9P0
9
7.4
2
45.333
012
12
9.8
3
34
020
20
16
5
61.2
029
29
24
7.5
42.207
038
38
31
10
32.211
055
55
45
15
22.255
073
73
60
20
16.767
093
93
76
25
13.161
110
110
90
30
11.127
Drive Current
Rating Code
DC
Amps
AC Line
Amps
Hp
Set RTA Value Using TA
Potentiometer (Ohms)
4P1
4.1
3.3
2
59.707
6P0
6
4.9
3
40.8
010
10
8.2
5
40.8
014
14
11.4
7.5
29.143
019
19
15.5
10
64.421
027
27
22.1
15
45.333
035
35
28.6
20
34.971
045
45
36.8
25
27.2
052
52
42.5
30
23.538
073
73
59.6
40
16.767
086
86
70.3
50
14.233
100
100
81.7
60
12.24
129
129
105.4
75
9.488