Rockwell Automation Publication 20P-TG001C-EN-P - February 2018
79
Part Replacement Procedures
Chapter 3
Table 18 - 230V AC Input Drives
Table 19 - 460V AC Input Drives
2. Continue with Install the Configured Pulse Transformer Circuit Board
and the Switching Power Supply Circuit Boards.
Install the Configured Pulse Transformer Circuit Board and the
Switching Power Supply Circuit Boards
Follow these steps to the configured pulse transformer and switching power
supply circuit boards.
IMPORTANT
A blank cell below a switch in
indicate that the setting
is “OFF”.
Drive
Current
Rating
Code
DC
Amps
AC Line
Amps
Hp DIP Switch S3
DIP Switch S4
S3-1
S3-2
S3-3
S3-4
S3-5
S3-6
S3-7
S3-8
S4-1
S4-2
S4-3
S4-4
S4-5
S4-6
S4-7
S4-8
7P0
7
5.7
1.5
ON
ON
ON
9P0
9
7.4
2
ON
ON
ON
012
12
9.8
3
ON
ON
ON
020
20
16
5
ON
ON
ON
029
29
24
7.5
ON
ON
ON
038
38
31
10
ON
ON
055
55
45
15
ON
ON
ON
ON
073
73
60
20
ON
ON
ON
ON
093
93
76
25
ON
ON
ON
ON
110
110
90
30
ON
ON
ON
ON
Drive
Current
Rating
Code
DC
Amps
AC Line
Amps
Hp DIP Switch S3
DIP Switch S4
S3-1
S3-2
S3-3
S3-4
S3-5
S3-6
S3-7
S3-8
S4-1
S4-2
S4-3
S4-4
S4-5
S4-6
S4-7
S4-8
4P1
4.1
3.3
2
ON
ON
ON
6P0
6
4.9
3
ON
ON
ON
010
10
8.2
5
ON
ON
ON
014
14
11.4
7.5
ON
ON
ON
019
19
15.5
10
ON
ON
ON
027
27
22.1
15
ON
ON
ON
035
35
28.6
20
ON
ON
ON
045
45
36.8
25
ON
ON
ON
ON
052
52
42.5
30
ON
ON
ON
ON
073
73
59.6
40
ON
ON
ON
ON
086
86
70.3
50
ON
ON
ON
100
100
81.7
60
ON
ON
ON
ON
129
129
105.4
75
ON
ON
ON
ON