Rockwell Automation Publication 20P-TG001C-EN-P - February 2018
73
Part Replacement Procedures
Chapter 3
14. Remove the cable from connector XUV on the left side of the switching
power supply board.
15. Remove the four M3 x 6 mm screws and washers that secure the
switching power supply board to the stand-offs on the back of the pulse
transformer board. Remove the switching power supply board.
16. Remove the plastic stand-off and nut that secures the switching power
supply board to the back of the pulse transformer board.
15
14
Tightening torque:
1.0 N•m (8.9 lb•in)
Secure nut
16