ControlNet Objects
C-5
Instance Attributes
Important:
Setting a register object attribute can only be accomplished
through a connection with a non-zero control timeout
attribute.
Register Object
(Continued)
Attribute
ID
Access Rule
Name
Data Type Description
1
Get
Bad Flag
BOOL
If set to 1, then attribute 4 may contain
invalid, bad or otherwise corrupt data.
0 = good
1 = bad
2
Get
Direction
BOOL
Direction of data transfer
0 = Producer Register (Drive to ControlNet)
1 = Consumer Register (ControlNet to Drive)
3
Get
Size
UINT
Size of register data in bits
4
Conditional
(1)
Data
ARRAY of
BITS
Data to be transferred
(1)
The access rule of Set is optional if attribute 2, Direction = 1. If Direction = 0, the access rule is
Get.
Service Code
Implemented for:
Service Name
Class
Instance
0x0E
Yes
Yes
Get_Attribute_Single
0x10
Yes
Yes
Set_Attribute_Single
20COMM-UM003A-EN-P.book Page 5 Wednesday, November 7, 2001 3:46 PM
Summary of Contents for PowerFlex 20-comm-c FRN 1. Series
Page 6: ...iv Table of Contents Notes 20COMM UM003A EN P book Page iv Wednesday November 7 2001 3 46 PM...
Page 18: ...1 8 Getting Started 20COMM UM003A EN P book Page 8 Wednesday November 7 2001 3 46 PM...
Page 114: ...B 6 Adapter Parameters Notes 20COMM UM003A EN P book Page 6 Wednesday November 7 2001 3 46 PM...
Page 152: ...Glossary 6 Notes 20COMM UM003A EN P book Page 6 Wednesday November 7 2001 3 46 PM...