Relay Electrical Life Expectancy/Peripheral Devices

Electrical Life Expectancy Curve for Electro-Mechanical Relays (Reference Values)

500

300

100

50

30

10

5

3

1

0

1

2

3

4

5

6

Switching current (A)

Lif

e (

×

 10

4

 oper

ations)

900-TC16
250 VAC, 30V DC 
(resistive load)
cos

φ

 = 1

Peripheral Devices

Temperature Controller Connection to a Solid-State Relay (SSR)

The 12V DC output of a temperature controller is typically used to interface to an SSR, such as the Allen-Bradley Bulletin 700-Sx line. An SSR
provides high current (e.g., 40 A) switching capability plus longer life than a mechanical relay. See the Relays and Timers Selection Guide
(Publication 700-SG003x-EN-P) for additional information.

Bulletin 700-SX

Controller Configuration from Keypad

Controller configuration of parameters can be done using the four keys on the bottom of the controller along with the two LED displays. The
configuration system is structured, which means a set path must be followed to get from one parameter to another.
User manuals, which provide details about configuring the Bulletin 900-TCx controllers, are available on-line at the Literature Library web site

http://literature.rockwellautomation.com/idc/groups/public/documents/webassets/browse_category.hcst

:

500

300

100

50

30

10

5

3

1

0

1

2

3

4

5

6

Switching current (A)

Lif

e (

×

 10

4

 oper

ations)

900-TC8
250 VAC, 30 VDC 
(resistive load)
cos

φ

 = 1

y

Bulletin 900-TC8:Series B,  Publication 900-UM007C-EN-E

y

Bulletin 900-TC16: Series B,  Publication 900-UM007C-EN-E

y

Bulletin 900-TC32: Series A,  Publication 900-UM003B-EN-E

Summary of Contents for Bulletin 900-CONV

Page 1: ...SELECTION GUIDE BULLETIN 900 TC Single Loop Electronic Temperature Process Controllers...

Page 2: ......

Page 3: ...series A controllers MV Manipulated Variable Display Yes No PF Key addition to keypad allows one touch assignment of Auto Manual Run Stop etc Yes No Thermocouple Types Added W and PL II Yes Yes Thermo...

Page 4: ...x Heating Cooling Control Mode Yes Yes Yes Control Method ON OFF or 2 PID auto tune and self tune with time proportioning ON OFF outputs or Analog Output 900 TC8 900 TC16 Inputs Thermocouple Input and...

Page 5: ...tput Type Supports Heater Burnout Open and Heater Short Circuit Alarm Controller Cat No 900 TC16 97 1 16 DIN 48 mm W x 48 mm H x 78 mm D Thermocouple or RTD 100 240V AC 2 Relay Output Yes 900 TC16RGTU...

Page 6: ...8COM B Event Input Unit Event inputa 900 TC8EIM 900 TC16 Communications and 1 Phase Heater Burnout Unit and Heater Short RS 485 communications with single phase heater burnout open and heater short ci...

Page 7: ...lder Personal Computer Configuration Software for Bulletin 900 TC32 Temperature Controllers available in CD format only 900 BLDSW1 Current Transformer Use with Bulletins 900 TC8 and 900 TC16 Only for...

Page 8: ...alfunction y After connecting the Conversion Cable to the computer check the COM port number before starting communications The computer requires time to recognize the cable connection This delay does...

Page 9: ...TC16 Bulletin 900 TC32 SUB SUB or Amber 6 MANU Manual Mode Lights when the controller mode is in manual 7 Key Lights when thesettings change protection is ON Keys disabled failure open or short A SUB...

Page 10: ...100 0 200 0 2300 Usable in the following ranges by scaling 1999 to 9999 or 199 9 to 999 9 1800 1700 1700 0 0 3 1 0 0 3 1 0 0 3 1 0 5 8 0 5 8 0 5 8 600 500 0 500 0 500 0 400 0 400 400 0 400 400 0 260...

Page 11: ...Cu CuNi DIN 43710 1985 7 JPt100 JIS C1604 1989 JIS C1606 1989 Pt100 JIS C1604 1997 IEC 751 The non contact temperature sensor must be configurable for type K thermocouple output within either of the...

Page 12: ...TC8 900 TC16 SPST NO 250V AC 3 A 30V DC 5 A max resistive load electrical life 100 000 operations min load 1V 1 mA 900 TC32 SPST NO 250V AC 1 A 30V DC 2 A max resistive load electrical life 100 000 o...

Page 13: ...Conformed Standards General Environmental Ratings Conforms to EN61010 1 IEC 61010 1 and VDE 0106 part 100 finger protection when the terminal cover is installed Pollution Level 2 Overcurrent Category...

Page 14: ...900 TC8 RS 232C or RS 485 2 wire half duplex 900 TC16 RS 485 2 wire half duplex 900 TC32 RS 485 2 wire half duplex Synchronization Method Start stop synchronization Protocol 900TC or Modbus RTU Slave...

Page 15: ...units are mounted together make sure that the surrounding ambient temperature does not exceed the allowable operating temperature specification Safety Terminal Cover9 Bulletin 900 TC16 Panel Cutouts y...

Page 16: ...it so that it is waterproof apply the waterproof gasket to the unit y When two or more units are mounted together make sure that the surrounding ambient temperature does not exceed the allowable opera...

Page 17: ...tect the Bulletin 900 TC8 900 TC16 and its lines from external noise y Solderless lugs are recommended when wiring to the Bulletin 900 TC8 900 TC16 wire terminals However if lugs are not used the cont...

Page 18: ...input terminals output terminals and communication terminals If reinforced insulation is required provide additional insulation such as spatial distance or material insulation as defined by IEC 60664...

Page 19: ...quivalent cable provides the physical connection between the converter and the PC RS 485 allows linking up to 31 controllers with a single personal computer Series B provides baud rates up to 57 6 K b...

Page 20: ...come in contact with the case 1 Insert the Bulletin 900 TC8 into the mounting hole in the panel from the front panel thickness 1 to 8 mm Ensure the waterproof gasket is in place if this is a UL Type 4...

Page 21: ...tin 900 TC32 can quickly be replaced by removing the field terminal plate 1 Press in firmly on the fasteners at both sides of the terminals to unlock the terminal plate and pull it upwards 2 Remove th...

Page 22: ...ion Guide Publication 700 SG003x EN P for additional information Bulletin 700 SX Controller Configuration from Keypad Controller configuration of parameters can be done using the four keys on the bott...

Page 23: ...mm H x 78 mm D 100 240V AC 900 CONVZ25 24V AC DC 900 CONVU25 7 Converts personal computer RS 232 USB communications to RS 485 Use for interface with a single Bulletin 900 TCx or multiple up to 31 con...

Page 24: ...t to IP20 when terminal cover mounted Terminals Equivalent to VDE 0106 100 when terminal cover mounted Memory Protection No protective functions communications data is not protected for power interrup...

Page 25: ...switch is set to OFF 12 SDB Note Terminals 2 and 10 are not used Terminal Specifications Make sure to check the input and output specifications for the signal pins of connected devices before connecti...

Page 26: ...le of Contents Product Selection 26 y 300 MHz CPU y 650 MB free disk space y SVGA resolution monitor XGA recommended y Microsoft Windows supported mouse y Available serial 9 pin COM port COM address 1...

Page 27: ...y Microsoft Windows 95 y Microsoft Windows 98 y Microsoft Windows NT 4 0 service pack 6 y Microsoft Windows 2000 y Provides a Graphic Configuration Option to Using the Bulletin 900 TC32 Controller s...

Page 28: ...Visit our website www ab com catalogs Bulletin 900 TC Single Loop Temperature Process Controller Notes 28...

Page 29: ......

Page 30: ...Publication900 SG001D EN P September 2008 Copyright 2008 Rockwell Automation Inc All Rights Reserved Printed in USA...

Reviews: