Using High-Speed Outputs
Pulse Train Output
Function File
Sub-Elements Summary
The variables within each PTO sub-element, along with what type of
behavior and access the control program has to those variables, are listed
individually below. All examples illustrate PTO 0. Terms and behavior for
PTO 1 are identical.
Pulse Train Output Function File (PTO:0)
Sub-Element Description
Address
Data Format
Range
Type
User Program
Access
For More
Information
OUT - Output
PTO:0.OUT
word (INT)
2 or 3
control
read only
DN - Done
PTO:0/DN
bit
0 or 1
status
read only
DS - Decelerating Status
PTO:0/DS
bit
0 or 1
status
read only
RS - Run Status
PTO:0/RS
bit
0 or 1
status
read only
AS - Accelerating Status
PTO:0/AS
bit
0 or 1
status
read only
RP - Ramp Profile
PTO:0/RP
bit
0 or 1
control
read/write
CS - Controlled Stop
PTO:0/CS
bit
0 or 1
control
read/write
IS - Idle Status
PTO:0/IS
bit
0 or 1
status
read only
ED - Error Detected Status
PTO:0/ED
bit
0 or 1
status
read only
NS - Normal Operation Status
PTO:0/NS
bit
0 or 1
status
read only
JPS - Jog Pulse Status
PTO:0/JPS
bit
0 or 1
status
read only
JCS - Jog Continuous Status
PTO:0/JCS
bit
0 or 1
status
read only
ADI - Accel/Decel Pulses Independent
PTO:0/ADI
bit
0 or 1
control
read/write
JP - Jog Pulse
PTO:0/JP
bit
0 or 1
control
read/write
JC - Jog Continuous
PTO:0/JC
bit
0 or 1
control
read/write
EH - Enable Hard Stop
PTO:0/EH
bit
0 or 1
control
read/write
EN - Enable Status (follows rung state)
PTO:0/EN
bit
0 or 1
status
read only
ER - Error Code
PTO:0.ER
word (INT)
-2 to 7
status
read only
OF
(1)
(2)
- Output Frequency (Hz)
PTO:0.OF
word (INT)
(3)
0 to 20,000
control
read/write
word (UINT)
(4)
0 to 40,000
- Operating Frequency
Status (Hz)
PTO:0.OFS
0 to 20,000
status
read only
word (UINT)
0 to 40,000
JF
- Jog Frequency (Hz)
PTO:0.JF
0 to 20,000
control
read/write
word (UINT)
0 to 40,000
TOP - Total Output Pulses
To Be Generated
PTO:0.TOP
long word
(32-bit INT)
0 to
2,147,483,647
control
read/write
OPP - Output Pulses Produced
PTO:0.OPP
long word
(32-bit INT)
0 to
2,147,483,647
status
read only
ADP - Accel/Decel Pulses
PTO:0.ADP
long word
(32-bit INT)
control
read/write
(1) OF, OFS, and JF are signed 16-bit (-32768~32768) variables in MicroLogix 1100 Series A controller, but they are unsigned 16-bit (0~65535) variables in MicroLogix 1100
Series B controller.
(2) The variable range of OF, OFS, and JF is 0~20000 in MicroLogix 1100 Series A controller and it is 0~40000 in MicroLogix 1100 Series B controller.
(3) Applies only to MicroLogix 1100 Series A Controller
(4) Applies only to MicroLogix 1100 Series B Controller