4
Maintenance, cleaning, and disinfection
© 2021 Interflex Datensysteme GmbH
IF-191 Server Cabinet Lock
15
4 Maintenance, cleaning, and disinfection
NOTICE
Property damage due to improper cleaning
Use of inappropriate cleaning agents may damage the device.
u
Do not use any aggressive cleaning agents or disinfectants for cleaning.
u
If necessary, clean the surface with a soft, damp cloth.
u
Only use disinfection agents that are specifically intended for disinfecting sensitive metallic surfaces
and plastics.
5 Technical specifications
Power supply
Power consumption
Approx. 4,9 W
Equipment
Installation type
Compatible with all standard server cabinets,
with adapters for Rittal, Vertiv/Knürr, and Modulan
Reader
RFID: MIFARE® Classic/DESFire
LEGIC® advant/prime
Read range
Up to 2 cm, depending on the technology
General data
Degree of protection
IP30 or IP65
Standards
Compliant to IEC 62368-1
Dimensions (H x W x D)
235.55 x 40.00 x 29.23 mm
Housing material
Zinc die-casting/powder coating
Color
Black
Power supply via Ethernet
PoE IEE 802.3at of power class 3 (up to 12.95 W)
Ambient temperature
-25 °C to +55 °C
Humidity
Max. 95%, non-condensing