2
Initial operation
© 2021 Interflex Datensysteme GmbH
IF-191 Server Cabinet Lock
11
Rittal Server Cabinet Lock
Changing the rotation direction of the handle
The preset rotation direction can be changed:
1. Remove screws
1
2. Remove cover plate
2
3. Remove gear plate
3
and turn it around to make the row of teeth run on the other side of the
gearwheel
4. Put cover plate back into place and fasten it with screws
Drill hole for LAN cable
To insert the LAN cable and the cables for door sensors, a Ø 14mm hole must be drilled:
1. Bring Server Cabinet Lock and linkage into
closed
position
2. Hold the Server Cabinet Lock against the inside of the door and mark the area where the cables can
be inserted
3. Drill the hole within this marking
Installation
u
After pre-assembly, proceed as described for the standard cabinet.