background image

1

General information

© 2021 Interflex Datensysteme GmbH

IF-191 Server Cabinet Lock

3

1 General information

1.1 Short description

Server cabinets generally contain high-value equipment and sensitive
data that must be protected. The ISO 27001 standard for information
security requires that only authorized people have access to server
cabinets and that every access is logged.

The electronic IF-191 Server Cabinet Lock is the ideal solution to meet
the highest levels of security for a wide variety of applications in a
simple and cost-effective way.

The key feature of the IF-191 Server Cabinet Lock is that it can be
directly integrated into the IF-6020 and IF-6040 access control
systems, where time profiles and permissions are managed and
transferred to electronic credentials.

The Server Cabinet Lock reads the access permissions on credentials
by means of proven NetworkOnCard technology and allows authorized
users to open the server cabinet.

IF-191 is compatible with all standard server cabinets. Adapters for
cabinets from Rittal, Vertiv/Knürr, and Modulan are also available.

The Server Cabinet Lock is delivered with a fixed backset according to the ordered version. Subsequent
changes are not meant to be made.

Default

Rittal old

Modulan

Cabinet

Backset MD [mounting
dimension in mm]

Item Number

Comment

Default

22

060TLR03

Modulan

22-3

060TLR03

M-MD

Rittal

0

060TLR03S01

Push mechanism

Rittal (old)

42

060TLR03S10

R-MD

Vertiv

0

060TLR03S03

Push mechanism

Summary of Contents for Interflex IF-191 Series

Page 1: ...IF 191 Server Cabinet Lock NetworkOnCard FA 191 xxx...

Page 2: ...p 5 1 6 Safety and security instructions 5 2 Initial operation 6 2 1 Programming 6 2 2 Mounting to cabinet 6 3 Operation 13 3 1 Opening doors 14 3 2 Activating deactivating the permanently open mode 1...

Page 3: ...egrated into the IF 6020 and IF 6040 access control systems where time profiles and permissions are managed and transferred to electronic credentials The Server Cabinet Lock reads the access permissio...

Page 4: ...eing read n Black list for lost credentials prevents unauthorized access 1 3 Scope of delivery The package contains n IF 191 Server Cabinet Lock in the ordered variant n Associated mounting kit n 95 1...

Page 5: ...ct may be affected by electromagnetic or magnetic interference u Do not place the product directly next to devices that can cause electromagnetic or magnetic interference especially not near switching...

Page 6: ...ribed in the Interflex offline components document 2 2 Mounting to cabinet The Server Cabinet Lock can be mounted to all standard server cabinets In addition Interflex offers adapters for other server...

Page 7: ...3 4 9 7 8 6 5 1 Fastening screws 2 Lock housing 3 Grooves tapped holes 4 Server Cabinet Lock 5 LAN socket for PoE 6 Retaining clip with screw 7 Cover cap long 8 Cover cap short 9 Fastening screw for...

Page 8: ...eme GmbH IF 191 Server Cabinet Lock 8 2 Hang the Server Cabinet Lock in the cutout on the door and press the spindle into the locking mechanism 3 Screw the locking mechanism to the Server Cabinet Lock...

Page 9: ...ning clip with screw 6 5 Place the lock housing 4 on the spindle and fasten it to 1 As an alternative the locking mechanism on the cabinet can be used instead of the provided lock housing 6 Insert the...

Page 10: ...GmbH IF 191 Server Cabinet Lock 10 7 Connect the Server Cabinet Lock to the power supply via 5 The Server Cabinet Lock can alternatively be connected to power via the USB C socket on the bottom of th...

Page 11: ...eeth run on the other side of the gearwheel 4 Put cover plate back into place and fasten it with screws Drill hole for LAN cable To insert the LAN cable and the cables for door sensors a 14mm hole mus...

Page 12: ...r 060TLR67 2 4 washers with an inside diameter of 10mm 3 Mounting material of the original lock spindle extension Procedure u After pre assembly proceed as described for the standard cabinet Vertiv Se...

Page 13: ...one hand and turn it steadily The direction of rotation for opening the door is determined by the closing mechanism in the cabinet Carefully check in which direction there is no resistance 3 Open the...

Page 14: ...g the permanently open mode The NoC component provides for the Permanently open operating mode In this operating mode the door can be opened without further bookings Activation and deactivation of the...

Page 15: ...sitive metallic surfaces and plastics 5 Technical specifications Power supply Power consumption Approx 4 9 W Equipment Installation type Compatible with all standard server cabinets with adapters for...

Page 16: ...terflex Datensysteme GmbH Zettachring 16 70567 Stuttgart Germany 49 711 1322 0 interflex info allegion com www interflex de The contents of this document are accurate and reliable to the best of our k...