TROUBLESHOOTING
Abnormal condition
Cause
※
What is TDS (Total Dissolved Solids) ?
It means a total quantity of solids dissolved in water, i.e. calcium, magnesium, iron and other mineral solids.
23
AMS 4 0 0 0
AMS 4000S
Treatment
Main power lamp does not come on.
·Insufficient water inflow.
·A power cord is not properly
plugged in.
·Increase water inflow.
·Ensure that power cord is plugged
in correctly.
·The fuse is blown.
·The fuse is not inserted properly.
·Replace the fuse.
Ionized Water Lamp does not turn off
even after turning the tap off.
·Abnormality of power circuit board.
·Immediately pull the plug out of the
power socket and then contact the
selling agent for service.
On pH test with a reagent, acidic water
color gets yellow, but alkaline water
color indicates pH neutrality
·No alkalinity color appearance can be
the result from a chemical reaction
with carbonic acid in the water.
※
Alkalinity is in inverse proportion to
acidity, Therefore, showing an acidic
reaction means that inversely alkaline
water is generated from the unit
·Test pH value with Level 4 water
(strong alkaline water).
·Test pH value after having water
inflow into the unit for the time being
Power supply is suddenly
cut off during operation.
·Too high TDS. (total dissolved
solids)
·It is the apparatus' automatic function to
protect the unit mechanism from a
possible excessive electric current. The
unit will automatically re-operate after
cooling off.
Reduced output of ionized water
from the unit
·Filter is clogged.
·Filter clogging may be caused by
sudden inflow of seriously polluted
source water, even if a filter life is
still effective.
·Filter replacement is needed.
·Low inflow pressure.
·Take a hose away from the diverter
adaptor and make sure that diverter
valve is not clogged.
·Check water inflow pressure.
·The supply hose is kinked.
·Staighten the kinked hose
Output water comes out,
but alkaline water has the
neutral pH (no ionization).
The voice guide, "please check
the filter connection" is given.
·An authentically approved filter is
not used.
·An authentically approved filter is
used, but the filter cable is not
connected to the terminal
·Replace with the authentically
approved filter.
·Connect the filter cable to the filter
cable terminal