Application Setting > Event > Trigger (Manual test the response)
Whenever the camera detects abnormal events during the scheduled time, it will automatically
respond by performing trigger response. There are 2 types of trigger responses: alarm sending and
emailing the alarm or recorded image to the specified server. To use this function, enter the server
information by accessing Application Setting > Event > Event Server. You may perform manual test
as specified in this section once you complete the setting to ensure that all functions are working
properly.
The default status of the digital input pin is set as “Normal Open”, but users can change it to
“Normal Ground” by setting the page “Setting > Application > Event > Trigger”:
1. When alarm input is set to be “Normal Open”, then the external device connected to alarm input
pin should be in open status. So when the external device is triggered to close status, the alarm
input pin will be triggered.
2. On the contrary, when alarm input pin is set to be “Normal Grounded” then the external device
connected to alarm input pin should be in close status. So when the external device is triggered
to open status, the alarm input pin will be triggered.
(Please refer
Appendix B: External Alarm
A for detailed explanation.)
NOTE
:
It is recommended to set up the Trigger Setting page (Setting-> Application Setting-> Event-> Trigger) before install the
hardware alarm I/O!