3.12 Batch Control
Password
0000
Language
简体
繁體
ENG
한문
Switch Func
Default Pulse
Freq
Alarm
Contact output
Press
or
button to selected the output, Please
choose
the “Alarm”
1. Default 2. Pulse 3. Frequency 4. Alarm
Password login window
Input the password
Password: 0000
Language
Press
or
to selected the language
123.456 m3
+0.0000
m3/h
OPERATIONS
SET
ZERO ESC
ENT
ENT
ENT
ENT
In the normal display, press
ENT
button for 5 seconds, then it will go to next setting
In this setting, Press
or
button till you selected SET
Alarm Select
MAX MIN
BAT
DIR
Alarm Select
Press
or
button to “BAT”
1. Max(Upper-Alarm) 2. Min(Lower-Alarm) 3. Batch 4. Direction
ENT
Low Cutoff (%fs)
0
.0
Function for cutoff the low flowrate
Press
button to move, press
button to change the Value
Setting Range: 0.0% ~ 9.9%
Pls press
ENT
button for 5 seconds, then it will go back to the normal display.
ENT
ENT
PV Units
m
3
/h
L/h GPH
Kg/h t/h GPM
L/m m3/m …
URV m3/h
7
0.0000
Select Flow Engineer unit
Press
or
to select the Engineer unit
0: m3/h 1: L/h 2: GPH 3: Kg/h 4: t/h 5: GPM
6: L/m 7: m3/m 8: ml/h 9: ml/m 10: ml /s
Flow Range
Setting Flow Range, that’s mean 4-20mA and Pulse, frequency output max. Value
Press
button to move, Press
to change the Value
ENT
ENT