Once the Hearth Stones are installed inside the oven, the Log Support Tray can be inserted into the
slots that can be found at the bottom of the oven cavity back wall. (
See figure # 2
).
The Log Support Tray can now rest on top of
the Hearth Stones covering the Log Burner.
The Ceramic Log will rest on top of the Sup-
port Tray and
must be pushed all the
way back until it contacts the back
wall.
This is done to ensure that the flames from
the Log Burner wrap around the front of the
Log itself, providing radiant heat.
The Top Stone can be placed from the out-
side to rest on top of the oven cavity within
the locating brackets.
Once all the items are in place, the complete
assembly would look like
Figure # 3
on the
right.
GAS CONNECTION—LIQUID PROPANE (LP)
NEVER CONNECT THE PIZZA OVEN TO AN UNREGULATED GAS SUPPLY.
Before proceeding, ensure the oven is fitted for LP gas. Connecting to an improper gas type will result in
poor performance and increased risk of damage or injury. Total gas consumption (per hour) with all
burners set on “HI” is a follows:
Hearth Burner
21,200 BTUH
Log Burner
18,900 BTUH
The installation of this appliance must conform with local codes or, in the absence of local codes, to the
national fuel gas code, ANSI Z223.1a
-
1988. Installation in Canada must be in accordance with the
Standard CAN/ CGA
-
B149.1 Natural Gas Installation or CAN/CGA
-
B149.2, Propane Installation Code.
Manifold pressure with LP
Operating:
10.0” W.C.
Non
-
operating:
11.2” W.C.
L.P. TANK REQUIREMENTS:
Use only a standard 20 Lbs. (5 Gal.) propane gas cylinder (approx. 12” Ø / 18” tall). The tank must be
installed in the upright position. Do not use a dented or rusty LP tank as it may be hazardous and should
be checked by your LP supplier. Never use a cylinder with a damaged valve.
The LP gas cylinder must be constructed and marked in accordance with the specifications for LP gas
cylinders of the U.S. Department of Transportation (DOT) 4BA, 4BW, and 4E.with an ACME thread/
OPD (over fill protection device) installed.
The cylinder must be provided with a shut off valve terminating in an LP gas supply cylinder valve outlet
specified, as applicable, for connection type
QCC1
(CGA
-
791 or ACME threads) in the standard for com-
pressed gas cylinder valve outlet and inlet connections ANSI/CGA V
-
1.