12
Although
Alfresco
™ Gourment Grills does not provide the LP cylinder nor an enclosure for the Pizza
Oven, if one was to be used by the end user, we strongly recommend following the ANSI Z21.89
-
2013 /
CSA 1.18
-
2013 guidelines for proper ventilation requirements when using LP cylinders in an enclosure:
16.
An enclosure for an LP gas cylinder shall be ventilated by openings at the level of the cylinder
valve and at floor level. The effectiveness of the opening(s) for purposes of ventilation shall be de-
termined with the LP gas supply cylinder in place.
17.
This shall be accompanied by one of the following:
a.
One side of the enclosure shall be completely open; or
b.
For an enclosure having four sides, a top and a bottom (at least two) ventilation openings at
cylinder valve level shall be provided in the side wall, equally sized, spaced at 180 degrees
(3.14 rad), and unobstructed.
18.
Each opening shall have a total free area of not less than ½ in
2
/lb. (7.1 cm
2
/kg) of stored fuel ca-
pacity and not less than a total free area of 10 in
2
(64.5 cm
2
).
Example: 20 Lb. cylinder = 10 in
2
19.
The ventilation opening(s) shall be provided at floor level and shall have a total free area of not less
than ½ in
2
/lb. (7.1 cm
2
/kg) of stored fuel capacity and not less than a total free area of 10 in
2
(64.5
cm
2
).
20.
If ventilation openings at floor level are in a side wall, there shall be at least two openings. The bot-
tom of the openings shall be at floor level and the upper edge no more than 5 in (127 mm) above
the floor. The openings shall be equally sized, spaced at 180 degrees (3.14 rad) and unobstructed.
21.
Every opening shall have minimum dimensions so as to permit the entrance of a 1/8 in (3.2 mm)
diameter rod.
!
CAUTION
CYLINDERS MUST BE STORED OUTDOORS IN A
WELL VENTILATED AREA OUT OF THE REACH OF
CHILDREN.
DISCONNECTED LP CYLINDERS MUST HAVE THREADED
VALVE PLUGS TIGHTLY INSTALLED, AND MUST NOT BE
STORED IN A BUILDING, GARAGE OR ANY OTHER ENCLOSED
AREA. THE GAS MUST BE TURNED OFF AT THE SUPPLY CYL-
INDER WHEN THE UNIT IS NOT IN USE. IF THE APPLIANCE IS
STORED INDOORS, THE CYLINDER MUST BE DISCONNECTED
AND REMOVED FROM THE APPLIANCE.
!
WARNING
YOUR ALFRESCO™ GOURMET GRILL’S
PRESSURE REGULATOR HAS A
MAXI-
MUM INPUT PRESSURE OF 14” WC.
(OR
APPROX. .5 PSI) , AND A
SAFETY LIMIT
OF 69” WC.
(2.5 PSI).
!
REGULATOR NOTICE
Exposure to pressures above the safety
limit of 69” WC. will permanently damage
the gas regulator requiring a replacement.
OVER
PRESSURE DAMAGE IS NOT
COVERED BY YOUR ALFRESCO
!
MISE EN GARDE
LE CYLINDRE DOIT ÊTRE STOCKÉ À L'EXTÉRIEUR
DANS UN ENDROIT BIEN VENTILÉ ET HORS DE LA POR-
TÉE DES ENFANTS.
DÉBRANCHER LES BOUTEILLES DE LP DOIVENT
AVOIR DES BOUCHONS DE VALEUR VISSÉS
HERMÉTIQUEMENT INSTALLÉS, ET NE DOIVENT
PAS ÊTRE STOCKÉS DANS UN BÂTIMENT, GARAGE
OU TOUT AUTRE ESPACE FERMÉ. LE GAZ DOIT
ÊTRE ARRÊTÉ AU NIVEAU DU CYLINDRE D'ALIMEN-
!
AVERTISSEMENT
VOTRE RÉGULATEUR DE PRESSION AL-
FRESCO GOURMET GRILLADES A
UNE
PRESSION D'ENTRÉE MAXIMALE DE 14"
WC
(OU ENVIRON 0,5 PSI), ET
UNE LIM-
ITE DE SÉCURITÉ DE 69" WC (2,5 PSI).
Summary of Contents for AXE-PZA