![alfaplam GRANDE Instruction For Use & Installation Instructions Download Page 12](http://html.mh-extra.com/html/alfaplam/grande/grande_instruction-for-use-and-installation-instructions_2895602012.webp)
12
NOT allow children and animals approach the pellet boiler
PLEASE FOLLOW THE REQUIREMENTS OF THIS DOCUMENT
For proper use of the boiler it is necessary:
-
To use only and exclusively the fuel specified by the manufacturer of the boiler
-
To take into account instructions for use
-
To clean the firebox every day (only when the boiler and the ash in it are cold)
-
When using low-quality pellet, firebox cleaning can be done twice a day
-
Not to use a pellet boiler in the event of malfunctions or anomalies, strange sound or suspected
defects
-
Not to pour water on the boiler and not to put out the fire in the furnace using water
-
Not to lean on the boiler as there is danger of its being unstable
-
Pellet boiler should not be used as a support or an object of attachment
-
Not to touch painted parts of the boiler during its operation
-
Not to use wood or coal but only pellets of the following characteristics: diameter 6 mm, length 30 mm,
humidity up to 10%
-
Not to use the boiler as ignition device
-
To carry out all operations as completely safe
6.0 INSTRUCTIONS FOR CORRECT COMMISSIONING AND CLEANING
Never use fuel oil, oils for lamps or any other oil for starting the pellet boiler. Store such oils away from
the boiler.
Never run the pellet boiler if the door glass is damaged. Do not hit the glass to avoid damaging.
Do not open the firebox to clean the glass while the boiler is operating.
When the boiler is turned off, clean the boiler with a cotton cloth or paper towel intended for cleaning
glass.
Make sure the pellet boiler is installed correctly and secured.
Make sure the door of the firebox of a pellet boiler is properly closed when the boiler is operating.
Carry out ash suction only if the pellet boiler is cold.
Do not use abrasive cleaners for pellet boilers.
6.1 REGULAR MAINTENANCE AND CLEANING OF PELLET BOILERS
Use of a vacuum cleaner with separator will make your job in cleaning the ash from the boiler easier.
Before you start with the maintenance (cleaning), remember the following safety tips:
Turn off the pellet boiler before you start any cleaning job.
Make sure that the ash in the firebox is cool.
-
Suck up ashes from the firebox at least once a week.
-
Vacuum and carefully clean the ashtray (only when the firebox is cold) at least once a week.
-
At least once a month, open the door on the right side of the boiler and clean (vacuum) the ash piled
beneath the heat exchanger.
It is always necessary that the pellet boiler and the ash are cold.
"Ashtray" in the firebox, Figure 13 below, must be inspected at least once a week and cleaned, if necessary. When
installing ashtray in the firebox it is necessary to make sure that it has been properly positioned so as not to cause
the malfunction of the boiler.