background image

 

17

14 

Outlet water 
temperature not right 
(too low) 

Low calorific value of 
fuel. 

Change fuel. 

Oversized heating 
system (too many 
radiators) 

Turn off some radiators. 

Not enough fuel has 
been loaded in the 
firebox. 

Increase the quantity of fuel in the firebox. 

15 

Fire is not burning 
properly? 

 
Low chimney draft. 
 

Build a new chimney or repair the old one. 

 
Connecting flue pipes 
are not sealed. 
Stove and chimney 
door are not sealed. 
Chimney draws “false 
air”. 
 

Seal all joints to prevent occurrence of “false air”. 

16 

Insufficient heat for 
baking or cooking. 

 
Thermostat set to a low 
temperature. 
 

Increase water temperature using the thermostat or 
briefly open the ash pan door. 

17 

Excessive heat for 
baking or cooking. 

 
Thermostat set to a 
high temperature. 
 

Reduce water temperature using the thermostat or burn 
a smaller fire. 

18 

Boiler-stove is smoking 
when used for the first 
time. 

 
Slight burning and 
heating of chimney and 
stove. 
 

It is normal for the stove to smoke a little during first 
time use and it stops after a while. 

19 

Boiler-stove is smoking 
during regular use. 

 
Chimney, flue pipes 
and stove not cleaned. 
 

Clean the inside of the chimney, flue pipes and stove. 

 
Wet fuel or you are 
using fuel that is 
generating a lot of 
smoke. 
 

Change fuel. Use dry fuel or smokeless fuel. 

 
Firebox is overloaded. 
 

Gradually fill the firebox, in several steps. 

Poor quality chimney. 

 
Repair your chimney or build a new one. 
 

20 

Grate is stuck during 
shaking. 

 
A nail, debris or other 
material is stuck on the 
grate. 
 

Clean the grate from unwanted objects. 

 

 

 

 

 

 

 

 

 

Summary of Contents for ALFA TERM-27

Page 1: ...STOVE USED FOR LOCAL HEATING ALFA TERM 27 INSTALLATION SETUP AND OPERATION INSTRUCTIONS...

Page 2: ...IONS Width 315 mm Height min max 264 460 mm Depth 414 mm FIREBOX DOOR OPENING width height 175 200 mm FLOW AND RETURN PIPE CONNECTIONS R1 RS THERMO VALVE AND SAFETY VALVE CONNECTIONS R1 2 RU COOLING P...

Page 3: ...pipe connection 21 Cleaning access plate 22 Handle 23 Grate support 24 Additional lid 25 Lever support 26 Tertiary air regulator knob 27 Tertiary air regulator cover 28 Cleaning access plate smaller...

Page 4: ...4 Figure 1...

Page 5: ...t and not on the side outlet The stove will reach its nominal heating capacity if the draft in the chimney is 20 Pa A chimney ensuring good draft is the basis of proper functioning of the stove The ch...

Page 6: ...walls it must be well insulated If the chimney connection is tightly connected to the chimney if the connection is extended If it is properly cleaned and free of birds nests dirt and soot If the flue...

Page 7: ...ation of the thermo valve safety pipe Item 6 is an R1 2 connection with an inner thread for safety valve installation 6 1 FLOW PIPE AND RETURN PIPE Fig 4 Items 1 and 2 and Fig 7 and 8 Items 3 and 10 T...

Page 8: ...R1 2 connection Fig 4 Item 6 is welded at the back of the boiler under the cooktop frame on which a safety valve MUST be fitted The safety valve should be 2 5 to 3 bars You can fit it directly on the...

Page 9: ...expansion vessel of 25 l and not more than 18 l which should be fitted on the return pipe as close to the boiler as possible and no block valves can be fitted between the boiler and expansion vessel...

Page 10: ...pe connection 3 Distribution pipe 4 Open expansion vessel 5 Safety valve 6 Radiator valve 7 Radiator 8 Air release valve 09 Circulation pump 10 Return pipe 11 Spigot for filling and discharge 12 Safet...

Page 11: ...em should be filled with water and well bled and the stove should be properly connected to the chimney as described in the foregoing items NOTE The stove may not be used without water It must be conne...

Page 12: ...of the grate and pull it out of its holder Place the grate on the supports 4 pcs welded inside the boiler firebox at the front and in the back 2 2 pcs Fig 1 Item 23 Place the grate at an angle slante...

Page 13: ...e damper used for starting the fire must be closed and power regulator must be open After you finish baking cooking or frying place the power regulator in desired position While baking increase the te...

Page 14: ...cloth cleaning agents and mild detergent instead Clean the oven after each use while still hot After cleaning leave the oven door open for a few minutes to prevent bad odors the next time you heat the...

Page 15: ...n all valves in the heating system and enable normal water circulation in the system Circulation pump failure Repair or replace the circulation pump to enable heating system operation Power outage Ope...

Page 16: ...mp speed Replace pump nuts or the entire pump 10 Noise murmur coming from the heating system Pump speed is too high Lower the speed Air in the system Bleed the air from the heating system Loose knobs...

Page 17: ...oor 17 Excessive heat for baking or cooking Thermostat set to a high temperature Reduce water temperature using the thermostat or burn a smaller fire 18 Boiler stove is smoking when used for the first...

Page 18: ...ses if the damage has occurred during transportation after the device was sold if the defects occurred due to improper mounting improper maintenance or mechanical damaging by the buyer if the defect o...

Page 19: ...19 Outline dimensions of ALFA TERM 27 stove Figure 16...

Reviews: