18/25
ALFA IN a.s.
©
www.alfain.eu
of the protective gas.
9.
By means of the button
V20
select TIG 2T or 4T. The appropriate LED
V15
,
V16
will shine.
10. By means of the button
V23
select the welding current mode (AC or DC).
Method must have the appropriate tungsten electrode and grinding
method. The appropriate LEDs
V24
,
V25
,
V26
,
V27
will shine.
11. By means of the encoder
V22
set the required welding current.
12. The others parameters (TIG parameters curve) is possible modify by
means of the encoder
V22
. The appropriate LED will shine. The required
parameter is automatically saved, when you go over to the next parameter
or after 3 s of the encoder inactivity. For more information see COOLING
UNIT
Fig. 2 – Cooling unit
Pos.
Description
B1
Quick connector (blue)
B2
Quick connector (red)
B3
Tank for cooling liquid
B4
Connector for connecting the cooling unit to the machine
B5
Quick connector (blue)
B6
Quick connector (red)
7. Like cooling liquid use ACL 15 or Binzel BTC 15. Avoid pollution of the
cooling liquid with mechanical dirt, grease, possibly with other, especially
flammable substances.
8. If the error message
“E11 - Lack of liquid“
illuminates during operation,
turn off the main switch
A8
and check or refill the cooling liquid. After
turning on the machine, perform the test of the cooling unit. If the error
repeats, it is necessary to find out the cause of the error.
9. Note: If is connected the gascooled torch, it is necessary to connect quick
connectors with connecting hose of liquid circuit! If this condition is not met,
it can cause the pump damage.
13. OPERATING PANEL.
14. You can start welding.
Caution Make sure, that in gascooled torch welding method is the cooling
unit turned off. At turning of the cooling unit on and at choise of the gascooled
torch can happened the pump damage.
BALANCE FUNCTION IN AC MODE
Function allows to set the ratio between the cleaning effect (plus part of the
wave) and the penetration (minus part of the wave).