17/25
ALFA IN a.s.
©
www.alfain.eu
turn off the main switch
A8
and check or refill the cooling liquid. After
turning on the machine, perform the test of the cooling unit. If the error
repeats, it is necessary to find out the cause of the error.
6. Note: If is connected the gascooled torch, it is necessary to connect quick
connectors with connecting hose of liquid circuit! If this condition is not met,
it can cause the pump damage.
15. OPERATING PANEL.
16. You can start welding.
TIG MODE WITH GASCOOLED TORCH
Fig. 7 – Getting started TIG with gascooled torch
1.
Insert the mains plug into a suitable 3x400 V mains socket, 50-60 Hz.
2.
Connect the gascooled torch to the front panel, see fig. above.
3.
Connect the earting clamp to the quick connector (+)
A4
.
4.
Connect the gas hose to the gas cylinder connector on the gas bottle and
to the connector
A6
on the rear panel.
5.
Switch the machine on by the main switch
A8
.
6.
By means of the button
V1
select method TIG LIFT or TIG HF, LED
V29
or
V30
will shine.
7.
By means of the button
V12
select the gas cooling of the torch. LED
V13
will shine.
8.
By means of the torch button activate the gas test and set the required flow