22
Er15
Power outage
Power outage during
boiler operation
Press and hold P2
key longer than 3
seconds
Check system and
installation
Contact service
Er16
Communication error between
electronics and display
Display cable
interruption
Press and hold P2
key longer than 3
seconds
Check display
cables and
connectors
Damage to the display
cable connectors
Contact service
Er17
The primary air flowmeter error
The primary air
flowmeter is not
adjusting the boiler
operation
The boiler
continues to
operate without
primary air
adjustment.
To reactivate the
primary air
flowmeter shut
down the stove.
Allow the boiler to
shut down and
then press and
hold P2 key longer
than 3 seconds
Check soiling of
primary air
opening and pipes
Check soiling and
draft of flue gas
pipes and chimney
Contact service
Er39
The primary air flowmeter sensor is
damaged
Faulty sensor
The boiler
continues to
operate without
primary air
adjustment
Contact service
Er41
Minimal primary air flow not
reached during the validation phase
An obstacle or major
soiling of the primary
air pipe
Allow the boiler to
shut down and
then press and
hold P2 key longer
than 3 seconds
Check and clean
primary air inflow
pipes
Check soiling and
draft of flue gas
pipes and chimney
Obstruction of flue gas
pipes
Inadequately closed
door during the ignition
phase
Check if the
chamber door
close correctly
Contact service
Er42
Primary airflow is greater than the
maximal allowable value
Excessive amount of
air inflow
Allow the boiler to
shut down and
then press and
hold P2 key longer
than 3 seconds
Check the pipe for
primary air inflow
Check soiling and
draft of flue gas
pipes and chimney
Contact service
Attention: If the recommended solution fails to remove the direct cause of the alarm CONTACT ALFA PLAM CALL
CENTER or the closest authorized service
11.
INFORMATION ON THE DISPOSAL AND STORAGE OF THE
BOILER
Disposal of the boiler and its removal (as waste material) is under the responsibility of the owner of the boiler.
The owner must comply with the applicable regulations of the state where the boiler is disposed, for sake of safety and
environmental protection.
Disposal of the boiler can be delegated to a third party that is licensed for such work.
INDICATION: In any case, you have to respect the laws of the state in which the pellet boiler is installed.
WARNING: All disassembled parts that should be destroyed must be properly removed:
-
remove all electrical components