14
Er16
Communication error RS485
Er17
Airflow regulator error
Er18
No pellet
Er25
Cleaning motor error
Er39
Airflow regulator broken
Er41
Minimum airflow in CHECK UP phase not reached
Er42
Maximum airflow reached
Er47
Auger encoder signal error
Er48
Unable to adjust the number of revolutions of auger motor
Er52
Module error I/O I2C
Other messages:
Sond
This message during Check-Up phase indicates that the temperature on one or
more probes equals the minimum value (0°C) or maximum value (depending on the
type of probe). Check that the probe is not open (0°C) or in short circuit (maximum
value on temperature scale).
Service
This message indicates that the planned number of working hours has been
reached and it is necessary to call the service.
Clean
This message indicates that the planned number of working hours has been
reached and it is necessary to clean the boiler.
Block Ignition
This message appears if the system shuts down while in Ignition phase. The
system will stop only when it switches to Run Mode.
Link Error
This message informs there is no communication between LCD display and the
controller in the boiler.
Standby Man
Appears if the system is in Standby Mode due to pressed P5 key
-
Visualizations:
By pressing keys P4 and P6 you enter the Visualization Menu. In this menu some values of system parameters can be
seen.
L3 On P1 Pump
LED number and state of pump out
L4 Off Safety Valve
LED number and state of out Aux 1
L5 Off Out not used
LED number and state of additional motor out
L6 On Load Engine
LED number and state of out Aux 2
L7 Off Out not used
LED number and state of out Aux 3
Exhaust T.:103
Temperature of flue gases (°C)
Water T.: 55
Water temperature (°C)
Buffer T.: 52
*Buffer temperature (°C)
Room T.: 21
*Room temperature (°C)
Pressure: 1548
*Water pressure in the boiler (mbar)
Air Flux: 680
The flow rate of primary air (cm/s)
Speed Fan: 1000
Flue gases fan speed/voltage (rpm/V)
Auger ON: 800
Auger motor speed/voltage (rpm/V)
Product Code 448-0000
System Code
FSYD01000135.0.2
Controller firmvera version
PSYSF01000209.0.2
Display firmvera version
*In case the boiler configuration has no installed probes these values are not visible.
Menu
The Menu consists of the User Menu and the Technical Menu.
The Technical Menu includes settings and adjustments which allow the manufacturer to modify parameters and system
configuration. The Technical Menu is not available to user but only to the authorized representative of the manufacturer.
User Menu
By pressing P3 key User Menu opens.