background image

19 

Wrong flue installation 

Contact the 
service 

Faulty manometer 

Er03 

Shutting down due to the low flue 
gases temperature 

Poor combustion (too much 
or too little of pellet remains in 
the firebox) 

Wait for the boiler to turn 
off and then start the 
system from the ON/OFF 
menu 

Check the 
size of the 
pellet 
granules  
Check if the 
boiler 
chamber is 
dirty 

Empty pellet tank 

Check the 
state of the 
flue pipes 

Faulty flue gases probe 

Contact the 
service 

Er05 

Shutting down due to the high flue 
gases temperature 

The flue gas temperature 
exceeds the limit 

 
Wait for the boiler to turn 
off and then start the 
system from the ON/OFF 
menu 

Insufficient 
heat transfer 
– contact the 
service 

Flue gas outlet obstruction 

Check if the 
flue pipes 
and the flue 
are dirty 

Faulty flue gases probe 

Er07 

Encoder error 

Encoder signal missing 

Wait for the boiler to turn 
off and then start the 
system from the ON/OFF 
menu 

 
Contact the 
service 

Er08 

Encoder error 

The flue gas motor is not 
responding 

Wait for the boiler to turn 
off and then start the 
system from the ON/OFF 
menu 

 
Contact the 
service 

The flue gas motor is working 
on a speed different from the 
set speed 

Er11 

Clock error 

Internal clock problems 

Turn the appliance off 
and then on in the 
ON/OFF menu 

Check the 
accuracy of 
the set time 

Insufficient internal battery 
capacity 

Check the 
accuracy of 
the chrono 
mode 
programming  
Contact the 
service 

Er12 

Boiler ignition failure 

Boiler ignition error 

Wait for the boiler to turn 
off and then start the 
system from the ON/OFF 
menu 

Check the 
used pellet 
state and 
quality 

The corresponding flue gas 
temperature was not achieved 
during the ignition phase 

Check the 
flue draft and 
cleanliness 

Faulty flue gases probe 

Contact the 
service 

Er15 

Power outage 

Power outage during the 
boiler operation mode  

Start the system from the 
ON/OFF menu 

Check the 
system and 
installation 
Contact the 
service 

Er16 

Communication error between the 
electronics and display 

Display cable interruption  

Turn the appliance off 
and then on in the 
ON/OFF menu 

Check the 
display cable 
and the 
connectors 

Display cable connector 
damage 

Contact the 
service 

Er17 

Primary air flow meter error 

The primary air flow meter is 
not adjusting the boiler  
operation 

The boiler continues to 
operate without primary 
air adjustment. To 
reactivate the primary air 
flow meter turn off the 
boiler. Wait for the boiler 
to turn off and then start 
the system from the 

Check of the 
primary air 
intake pipes 
are clean 
Check the 
exhaust and 
flue draft and 
cleanliness   

Summary of Contents for Grande 37 Lux

Page 1: ...37 Lux Instruction for use maintenance and installation This product meets the requirements of the Ecodesign Directive in terms of efficiency and air pollution level in order to contribute to the red...

Page 2: ...by a person authorized by Alfa Plam The flame that develops in the boiler during normal combustion of wood biomass releases just the amount of carbon dioxide CO2 that would be released by natural wood...

Page 3: ...CE 10 8 IMPORTANT SAFETY INFORMATION 11 9 PELLET QUALITY IS VERY IMPORTANT 11 9 1 PELLET STORAGE 11 10 BOILER CONTROL SYSTEM 11 10 1 Electrical connection diagram 12 10 2 Touch screen control panel di...

Page 4: ...ents and or damage occurred due to use of non original or inappropriate spare parts Installations is solely within the responsibility of the installer 2 1 MAIN USER RESPONSIBILITIES The boiler user mu...

Page 5: ...ommissioning inspect the operation during at least 30 minutes in order to check whether all requirements have been met After finishing the installation the installer should provide the customer with t...

Page 6: ...the 80 mm flue pipe Therefore make sure that the flue pipe is completely sealed Carefully analyze the position and condition of the space through which the flue passes If the flue pipe passes through...

Page 7: ...ent always turned upward Figure 4 We recommend not making long horizontal sections for the flue connection If there is no other possibility the flue pipes should not have a downward slope but upward t...

Page 8: ...7 AISI 316 steel flue with double insulated chamber material resistant to 400 C Optimal efficiency 100 Waterproof flue with double insulated chamber and outer casing of light concrete Optimal efficien...

Page 9: ...ng devices such as a hoods hair dryers fans etc located in the room with the boiler combustion air fresh air must be supplied from outside In any case this should be discussed with the competent chimn...

Page 10: ...e universal ones Check if the valve is easily opened check with a finger so that it could be opened with the pump s power The non return valve is placed behind each pump If there are multiple pumps yo...

Page 11: ...nting damage due to sudden failure of a component which may seriously endanger the safety of persons and or your property Clean the firebox and the space underneath it when cleaning the ashes 6 2 SAFE...

Page 12: ...to the following safety rules Turn the pellet boiler off before beginning any procedure Make sure that the ash is cold before beginning any procedure on the boiler Vacuum the ashes deposited in the c...

Page 13: ...ONS ENSURE THE MAXIMUM OUTPUT OF THE BOILER AND THE TEMPERATURE OF THE SYSTEM Make sure that the pellet boiler and ashes are cold For complete weekly cleaning or after 200 kg of used pellets whichever...

Page 14: ...he type and quality of the pellets The manufacturer is not in any way responsible for poor performance of the boiler due to the use of poor quality pellets If sawdust or small decomposed pellets are p...

Page 15: ...isplay 1 2 Start screen display 2 2 YELLOW GREEN POWER CABLE FLUE GAS FAN TURBULATOR REDUCER PRIMARY AIR FAN LIGTER AUGER REDUCER THERMOMETER MANOMETER PENDULUM REDUCER PUMP MICRO SWITCH 1 MICRO SWITC...

Page 16: ...Auger Auger on off Pump Pump on off Valve Pendulum reducer on off V2 Room fan on off V3 Turbulator reducer on off A1 Heater igniter on off A3 Pendulum reducer on off A5 Auger reducer blocked not bloc...

Page 17: ...ition failure Er15 Power outage longer than 50 minutes Er16 Communication error RS485 Er17 Airflow regulator error Er18 No pellet Er25 Firebox cleaning motor error Er26 Turbulator cleaning motor error...

Page 18: ...es Boiler Thermostat The adjustable boiler water temperature range is from 40 C to 80 C By setting the temperature of the water in the boiler the user sets the operating condition of the boiler i e th...

Page 19: ...the steps decreases and increases the calibrated auger speed Fan Calibration menu for changing the speed of the flue gas fan The system has 15 calibration steps from 7 to 7 the factory setting is 0 Th...

Page 20: ...s is performed during the check up phase During this phase the flue gases motor is working at maximum speed while the auger and the igniter are turned off The check up phase takes a few seconds and th...

Page 21: ...ases temperature exceeds 230 C or when the boiler water temperature reaches 85 C During this phase the pellet feed stops until the flue gases temperature is below 230 C or the water temperature in the...

Page 22: ...ck error Internal clock problems Turn the appliance off and then on in the ON OFF menu Check the accuracy of the set time Insufficient internal battery capacity Check the accuracy of the chrono mode p...

Page 23: ...t and cleanliness Contact the service NOTE If the recommended solution fails to remove the direct cause of the alarm CONTACT ALFA PLAM CALL CENTER or the closest authorized service 11 INFORMATION ON B...

Page 24: ...8 Flue gas temperature value at reduced power C 70 Mean NOx value at 10 O2 at rated power mg m3 191 Mean CO value at 10 O2 at rated power mg m3 26 Mean dust emission value at 10 O2 at rated power mg m...

Page 25: ...d floor heating Note If only floor heating is connected to the boiler make sure to install an accumulation tank BUFFER Legend 1 Pellet boiler 2 Air vent 3 Safety valve 3 bar 4 Three way mixing valve w...

Page 26: ...draulic installation diagram accumulation tank Legend 1 Pellet boiler 2 Air vent 3 Safety valve 3 bar 4 Air vent 5 Circulation pump 6 Three way mixing valve with pipe thermostat 7 Accumulation tank BU...

Reviews: