16
Temperature Unit – This option selects the temperature display in degrees Celsius (°C) or Fahrenheit (°F).
10.3. 4.2.
Service
The service menu provides various information about system conditions.
Counters – this option makes it possible to read information on the number of boiler starts, the number of failed starts
and the operating time in normal operation mode, modulation and safety mode.
Secondary Information – shows the states of the boiler elements listed in the table below.
Contacts
Description
Evo Code
Installed electronics code display (577)
Appliance number
Not shown
Combustion fan
Current no. of fan revolutions per minute
Auger
Current no. of auger revolutions per minute
V2 outlet
Turbulator reducer operation status
V3 outlet
Primary air fan operation status
A1 outlet
Heater-igniter operation status
Valve
(Empty contacts)
A3 outlet
Pendulum reducer operation status
Pump
Pump operation status
A5 outlet
Auger reducer operation status
Airflow
Current flow in m
³
/h
Smoke temperature
Current temperature of exhaust gases in
°
C
Water temperature
Current temperature of boiler water in
°
C
IN2 inlet
Status of (digital) auger encoders’ contacts
IN3 inlet
Status of (digital) inlets 3 contacts
IN8 inlet
Status of (digital) micro-switches 2 contacts
IN9 inlet
Status of (digital) micro-switches 1 contacts
HV1 inlet
Status of thermostat contacts
HV2 inlet
Status of manometer contacts
Auger Calibration – menu for changing the feeding speed of the auger. The system has 15 calibration steps (from -7 to
+7; factory set to 0). The calibration effect is valid in operating mode and in modulation. Decreasing and increasing the steps
decreases and increases the calibrated auger speed.
Fan Calibration – menu for changing the speed of the flue gas fan. The system has 15 calibration steps (from -7 to +7;
the factory setting is 0). The calibration effect is valid in operating mode and in modulation.
Note: Do not calibrate the auger and fan without first consulting an authorized service center or the manufacturer's
representative.
Auto Power – this menu allows you to adjust the power of the exhaust gases only in automatic mode.
Manual Load – this option allows you to calculate the amount of pellets used in 10 minutes if the service technician has
enabled this by adjusting the parameters. The system must be off to activate this function.
10.3. 4.3.
Sys tem Menu
This menu allows access to technical settings. Access is password protected and is only allowed to authorized technical
staff.
10.3. 4.4.
Displ ay m enu
The control display parameters are set in this menu.
Option
Description
Brightness
Adjusting the brightness of the touch screen
Minimum brightness
Adjusting the minimum brightness of the display when it not used
Standby display
The display enters standby mode to save power after a period of inactivity
Control panel address
Access allowed to authorized technical personnel
Reboot control panel
Enables the control panel software restarting
Sound
Adjusting the sound emitted by the panel on/off
Delete error list
Option to delete the error history list. Access provided by authorized technical personnel
Node list
Displaying all devices connected to the control panel via Modbus
Wallpaper
Selecting the home screen background
Control panel info
Panel technical characteristics
10.3. 5.
Info rm at ion Menu
The information menu shows the information on the current exhaust temperature (°C) and the current boiler water
temperature (°C)